Arcoaire D5CSRAH18AAK — Mini-Split Heat Pump Specifications
Arcoaire D5CSRAH18AAK (Mini-Split Heat Pump, PD ID 3556086) holds 1 ENERGY STAR certified SKU rated at 23.9 SEER2 — #2,010 of 2,096 (61 tied, beats 1.2% of peers), -1.20 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Arcoaire D5CSRAH18AAK — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.9 SEER2 and Heating Rating set at 13.5 HSPF2.
- Max SEER2
- 23.9 SEER2
- Heating Rating
- 13.5 HSPF2
- Heating COP
- 2.16 COP
- Cohort Rank
- #2,010/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3556086
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Arcoaire D5CSRAH18AAK rank across federal compliance and ENERGY STAR cohorts?
Arcoaire D5CSRAH18AAK ranks #2,010 of 2,096 (tied with 60 others at 23.9 SEER2, more efficient than 1.2% of certified series) for Max SEER2 (-1.20 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (77.1% capacity retention at 5F) (1.3 nominal Tons at 16,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2,010 of 2,096 (61 tied, beats 1.2% of peers) | -1.20 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 13.5 HSPF2 | +3.00 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.5 EER2 | -1.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 77.1% of 47F rating | 5F COP 2.16 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.9 SEER2 / 13.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Arcoaire D5CSRAH18AAK require?
Modeled utility figures for Arcoaire D5CSRAH18AAK (Arcoaire) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 669 kWh/yr | $109/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,222 kWh/yr | $363/yr at US median |
| Combined Annual Electricity Cost | $472/yr | State range: $368 (NV) to $1,364 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,228 kWh/yr | $364/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Arcoaire D5CSRAH18AAK?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Arcoaire D5CSRAH18AAK (PD ID 3556086).
| D5CSRAH18AAK | D5FSFAH16XAK | 16,000 BTU/h | 23.9 SEER2 / 13.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Arcoaire D5CSRAH18AAK, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Arcoaire D5CSRAH18AAK: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Arcoaire D5CSRAH18AAK exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Arcoaire D5CSRAH18AAK uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Arcoaire D5CSRAH18AAK fit | Single-family replacement needing documented ENERGY STAR PD ID 3556086 with matching indoor air handler. |
| Skip Arcoaire D5CSRAH18AAK if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Arcoaire D5CSRAH18AAK against Airquest D5CSRAH18AAK and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Arcoaire D5CSRAH18AAK compare with peer Mini-Split Heat Pump units?
Arcoaire D5CSRAH18AAK holds #2,010 of 2,096 (61 tied, beats 1.2% of peers) out of 2,096 verified mini-split heat pump models (-1.20 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 23.9 SEER2. Closest same-cohort alternatives include Airquest D5CSRAH18AAK.
Where is Arcoaire D5CSRAH18AAK compliant for 2026 US installation?
Arcoaire D5CSRAH18AAK: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Arcoaire D5CSRAH18AAK model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Arcoaire D5CSRAH18AAK runs 669 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Arcoaire D5CSRAH18AAK cover?
Arcoaire D5CSRAH18AAK covers 16,000-16,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Arcoaire D5CSRAH18AAK handle extreme weather or cold snaps?
Yes, Arcoaire D5CSRAH18AAK carries ENERGY STAR Cold Climate certification (77.1% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Arcoaire D5CSRAH18AAK?
Arcoaire D5CSRAH18AAK specifies R-454B compliance (PD ID 3556086); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Arcoaire D5CSRAH18AAK reach 23.9 SEER2?
Peak 23.9 SEER2 represents the top tested AHRI pairing for Arcoaire D5CSRAH18AAK (PD ID 3556086); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Arcoaire D5CSRAH18AAK?
Arcoaire D5CSRAH18AAK requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Airquest D5CSRAH18AAK.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.