Airquest D5CPRAH12AAK — Mini-Split Heat Pump Specifications
Airquest D5CPRAH12AAK (Mini-Split Heat Pump, PD ID 3624556) holds 1 ENERGY STAR certified SKU rated at 28.0 SEER2 — #250 of 2,096 (Top 12.5%, 13 tied), +2.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Airquest D5CPRAH12AAK — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 28.0 SEER2 and Heating Rating set at 12.7 HSPF2.
- Max SEER2
- 28.0 SEER2
- Heating Rating
- 12.7 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #250/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3624556
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | This series |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Airquest D5CPRAH12AAK rank across federal compliance and ENERGY STAR cohorts?
Airquest D5CPRAH12AAK ranks #250 of 2,096 (tied with 12 others at 28.0 SEER2, top 12.5%, more efficient than 87.5% of certified series) for Max SEER2 (+2.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (112.5% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #250 of 2,096 (Top 12.5%, 13 tied) | +2.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 12.7 HSPF2 | +2.20 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.5 EER2 | -0.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 112.5% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 28.0 SEER2 / 12.7 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Airquest D5CPRAH12AAK require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Airquest D5CPRAH12AAK estimates reflect 1 certified SKU combination tested under PD ID 3624556.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 429 kWh/yr | $70/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,362 kWh/yr | $386/yr at US median |
| Combined Annual Electricity Cost | $456/yr | State range: $355 (NV) to $1,317 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,048 kWh/yr | $334/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Airquest D5CPRAH12AAK?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Airquest D5CPRAH12AAK (PD ID 3624556).
| D5CPRAH12AAK | D5FPHAH12XAK | 12,000 BTU/h | 28.0 SEER2 / 12.7 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Airquest D5CPRAH12AAK, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Airquest D5CPRAH12AAK: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Airquest D5CPRAH12AAK exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Airquest D5CPRAH12AAK uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Airquest D5CPRAH12AAK fit | Single-family replacement needing documented ENERGY STAR PD ID 3624556 with matching indoor air handler. |
| Skip Airquest D5CPRAH12AAK if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Airquest D5CPRAH12AAK against Arcoaire D5CPRAH12AAK and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Airquest D5CPRAH12AAK compare with peer Mini-Split Heat Pump units?
Airquest D5CPRAH12AAK holds #250 of 2,096 (Top 12.5%, 13 tied) out of 2,096 verified mini-split heat pump models (+2.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 28.0 SEER2. Closest same-cohort alternatives include Arcoaire D5CPRAH12AAK.
Where is Airquest D5CPRAH12AAK compliant for 2026 US installation?
Airquest D5CPRAH12AAK: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Airquest D5CPRAH12AAK model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Airquest D5CPRAH12AAK runs 429 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Airquest D5CPRAH12AAK cover?
Airquest D5CPRAH12AAK covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Airquest D5CPRAH12AAK handle extreme weather or cold snaps?
Yes, Airquest D5CPRAH12AAK carries ENERGY STAR Cold Climate certification (112.5% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Airquest D5CPRAH12AAK?
Airquest D5CPRAH12AAK specifies R-454B compliance (PD ID 3624556); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Airquest D5CPRAH12AAK reach 28.0 SEER2?
Peak 28.0 SEER2 represents the top tested AHRI pairing for Airquest D5CPRAH12AAK (PD ID 3624556); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Airquest D5CPRAH12AAK?
Airquest D5CPRAH12AAK requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Arcoaire D5CPRAH12AAK.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.