AIR-CON ABHCI4H4S09 — Mini-Split Heat Pump Specifications

AIR-CON ABHCI4H4S09 (Mini-Split Heat Pump, PD ID 2740074) holds 1 ENERGY STAR certified SKU rated at 25.5 SEER2 — #769 of 2,096 (Top 45.6%, 188 tied), +0.40 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). AIR-CON ABHCI4H4S09 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.5 SEER2 and Heating Rating set at 10.5 HSPF2.

Max SEER2
25.5 SEER2
Heating Rating
10.5 HSPF2
Heating COP
2.05 COP
Cohort Rank
#769/2,096
Verified Combos
1 SKU
Sample PD ID
2740074
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
AIR-CON ABHCI4H4S09 Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. AIR-CON ABHCI4H4S09 sits at 25.5 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 25.5 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785This series
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
AIR-CON ABHCI4H4S09 residential equipment inspection. ThermalSpec Editorial Photography

How does AIR-CON ABHCI4H4S09 rank across federal compliance and ENERGY STAR cohorts?

AIR-CON ABHCI4H4S09 ranks #769 of 2,096 (tied with 187 others at 25.5 SEER2, top 45.6%, more efficient than 54.4% of certified series) for Max SEER2 (+0.40 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (77.8% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

AIR-CON ABHCI4H4S09 Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #769 of 2,096 (Top 45.6%, 188 tied) +0.40 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 10.5 HSPF2 Equal to 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 14.5 EER2 +0.50 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 77.8% of 47F rating 5F COP 2.05
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.5 SEER2 / 10.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.5 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule OLDER R-410A Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does AIR-CON ABHCI4H4S09 require?

Modeled utility figures for AIR-CON ABHCI4H4S09 (AIR-CON) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.

Cool_kWh = (9,000 BTU/h * 1,000 hrs / 25.5 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy353 kWh/yr$58/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,857 kWh/yr$467/yr at US median
Combined Annual Electricity Cost$524/yrState range: $408 (NV) to $1,514 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,419 kWh/yr$232/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to AIR-CON ABHCI4H4S09?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for AIR-CON ABHCI4H4S09 (PD ID 2740074).

ABHCI4H4S09 ABHEM4H4S09 9,000 BTU/h 25.5 SEER2 / 10.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on AIR-CON ABHCI4H4S09, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across AIR-CON ABHCI4H4S09: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for AIR-CON ABHCI4H4S09 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal AIR-CON ABHCI4H4S09 fitSingle-family replacement needing documented ENERGY STAR PD ID 2740074 with matching indoor air handler.
Skip AIR-CON ABHCI4H4S09 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare AIR-CON ABHCI4H4S09 against AC PRO AOX230-09HFN1-MW5W and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

AC PRO AOX230-09HFN1-MW5W

25.5 SEER2 · 12.3 HSPF2 · 9,000 BTU/h

AIREASE 4DHP2S09S-1P

25.5 SEER2 · 12.3 HSPF2 · 9,000 BTU/h

ALLIED 4DHP2S09S-1P

25.5 SEER2 · 12.3 HSPF2 · 9,000 BTU/h

Armstrong Air 4DHP2S09S-1P

25.5 SEER2 · 12.3 HSPF2 · 9,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does AIR-CON ABHCI4H4S09 compare with peer Mini-Split Heat Pump units?

AIR-CON ABHCI4H4S09 holds #769 of 2,096 (Top 45.6%, 188 tied) out of 2,096 verified mini-split heat pump models (+0.40 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.5 SEER2. Closest same-cohort alternatives include AC PRO AOX230-09HFN1-MW5W.

DOE Regions

Where is AIR-CON ABHCI4H4S09 compliant for 2026 US installation?

AIR-CON ABHCI4H4S09: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does AIR-CON ABHCI4H4S09 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, AIR-CON ABHCI4H4S09 runs 353 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does AIR-CON ABHCI4H4S09 cover?

AIR-CON ABHCI4H4S09 covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does AIR-CON ABHCI4H4S09 handle extreme weather or cold snaps?

Yes, AIR-CON ABHCI4H4S09 carries ENERGY STAR Cold Climate certification (77.8% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern AIR-CON ABHCI4H4S09?

AIR-CON ABHCI4H4S09 specifies R-410A compliance (PD ID 2740074); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in AIR-CON ABHCI4H4S09 reach 25.5 SEER2?

Peak 25.5 SEER2 represents the top tested AHRI pairing for AIR-CON ABHCI4H4S09 (PD ID 2740074); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to AIR-CON ABHCI4H4S09?

AIR-CON ABHCI4H4S09 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AC PRO AOX230-09HFN1-MW5W.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.

Comparable HVAC Climate & Cost Metros