AC PRO A4OG-36HFN1-M — Mini-Split Heat Pump Specifications
AC PRO A4OG-36HFN1-M (Mini-Split Heat Pump, PD ID 4016113) holds 1 ENERGY STAR certified SKU rated at 23.9 SEER2 — #2,010 of 2,096 (61 tied, beats 1.2% of peers), -1.20 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). AC PRO A4OG-36HFN1-M — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.9 SEER2 and Heating Rating set at 9.5 HSPF2.
- Max SEER2
- 23.9 SEER2
- Heating Rating
- 9.5 HSPF2
- Heating COP
- 1.8 COP
- Cohort Rank
- #2,010/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4016113
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does AC PRO A4OG-36HFN1-M rank across federal compliance and ENERGY STAR cohorts?
AC PRO A4OG-36HFN1-M ranks #2,010 of 2,096 (tied with 60 others at 23.9 SEER2, more efficient than 1.2% of certified series) for Max SEER2 (-1.20 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (3.0 nominal Tons at 36,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2,010 of 2,096 (61 tied, beats 1.2% of peers) | -1.20 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 9.5 HSPF2 | -1.00 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 11.7 EER2 | -2.30 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 68.1% of 47F rating | 5F COP 1.8 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.9 SEER2 / 9.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 11.7 EER2 |
| ENERGY STAR Cold Climate Spec | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does AC PRO A4OG-36HFN1-M require?
Modeled utility figures for AC PRO A4OG-36HFN1-M (AC PRO) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,506 kWh/yr | $246/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,158 kWh/yr | $516/yr at US median |
| Combined Annual Electricity Cost | $762/yr | State range: $593 (NV) to $2,200 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,853 kWh/yr | $303/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to AC PRO A4OG-36HFN1-M?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for AC PRO A4OG-36HFN1-M (PD ID 4016113).
| A4OG-36HFN1-M | Matched AHRI Coil | 36,000 BTU/h | 23.9 SEER2 / 9.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on AC PRO A4OG-36HFN1-M, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across AC PRO A4OG-36HFN1-M: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for AC PRO A4OG-36HFN1-M exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- AC PRO A4OG-36HFN1-M lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal AC PRO A4OG-36HFN1-M fit | Single-family replacement needing documented ENERGY STAR PD ID 4016113 with matching indoor air handler. |
| Skip AC PRO A4OG-36HFN1-M if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare AC PRO A4OG-36HFN1-M against 1HVAC ES-36Z-M4B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does AC PRO A4OG-36HFN1-M compare with peer Mini-Split Heat Pump units?
AC PRO A4OG-36HFN1-M holds #2,010 of 2,096 (61 tied, beats 1.2% of peers) out of 2,096 verified mini-split heat pump models (-1.20 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 23.9 SEER2. Closest same-cohort alternatives include 1HVAC ES-36Z-M4B.
Where is AC PRO A4OG-36HFN1-M compliant for 2026 US installation?
AC PRO A4OG-36HFN1-M: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does AC PRO A4OG-36HFN1-M model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, AC PRO A4OG-36HFN1-M runs 1,506 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does AC PRO A4OG-36HFN1-M cover?
AC PRO A4OG-36HFN1-M covers 36,000-36,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does AC PRO A4OG-36HFN1-M handle extreme weather or cold snaps?
AC PRO A4OG-36HFN1-M is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern AC PRO A4OG-36HFN1-M?
AC PRO A4OG-36HFN1-M specifies R-410A compliance (PD ID 4016113); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in AC PRO A4OG-36HFN1-M reach 23.9 SEER2?
Peak 23.9 SEER2 represents the top tested AHRI pairing for AC PRO A4OG-36HFN1-M (PD ID 4016113); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to AC PRO A4OG-36HFN1-M?
AC PRO A4OG-36HFN1-M requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ES-36Z-M4B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.