AC PRO.COM AWH12AGCXD-A3DNA1A/O — Mini-Split Heat Pump Specifications
AC PRO.COM AWH12AGCXD-A3DNA1A/O (Mini-Split Heat Pump, PD ID 2415288) holds 1 ENERGY STAR certified SKU rated at 24.0 SEER2 — #1,599 of 2,096 (411 tied, beats 4.2% of peers), -1.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). AC PRO.COM AWH12AGCXD-A3DNA1A/O — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.0 SEER2 and Heating Rating set at 9.0 HSPF2.
- Max SEER2
- 24.0 SEER2
- Heating Rating
- 9.0 HSPF2
- Heating COP
- 1.85 COP
- Cohort Rank
- #1,599/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 2415288
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does AC PRO.COM AWH12AGCXD-A3DNA1A/O rank across federal compliance and ENERGY STAR cohorts?
AC PRO.COM AWH12AGCXD-A3DNA1A/O ranks #1,599 of 2,096 (tied with 410 others at 24.0 SEER2, more efficient than 4.2% of certified series) for Max SEER2 (-1.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (73.3% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,599 of 2,096 (411 tied, beats 4.2% of peers) | -1.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 9.0 HSPF2 | -1.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.0 EER2 | -2.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 73.3% of 47F rating | 5F COP 1.85 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.0 SEER2 / 9.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does AC PRO.COM AWH12AGCXD-A3DNA1A/O require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, AC PRO.COM AWH12AGCXD-A3DNA1A/O estimates reflect 1 certified SKU combination tested under PD ID 2415288.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 500 kWh/yr | $82/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,333 kWh/yr | $544/yr at US median |
| Combined Annual Electricity Cost | $626/yr | State range: $488 (NV) to $1,808 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,006 kWh/yr | $164/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to AC PRO.COM AWH12AGCXD-A3DNA1A/O?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for AC PRO.COM AWH12AGCXD-A3DNA1A/O (PD ID 2415288).
| AWH12AGCXD-A3DNA1A/O | AWH12QCXD-A3DNB8A/I | 12,000 BTU/h | 24.0 SEER2 / 9.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on AC PRO.COM AWH12AGCXD-A3DNA1A/O, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across AC PRO.COM AWH12AGCXD-A3DNA1A/O: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for AC PRO.COM AWH12AGCXD-A3DNA1A/O exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal AC PRO.COM AWH12AGCXD-A3DNA1A/O fit | Single-family replacement needing documented ENERGY STAR PD ID 2415288 with matching indoor air handler. |
| Skip AC PRO.COM AWH12AGCXD-A3DNA1A/O if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare AC PRO.COM AWH12AGCXD-A3DNA1A/O against ACD PUD12KCH24S-O and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does AC PRO.COM AWH12AGCXD-A3DNA1A/O compare with peer Mini-Split Heat Pump units?
AC PRO.COM AWH12AGCXD-A3DNA1A/O holds #1,599 of 2,096 (411 tied, beats 4.2% of peers) out of 2,096 verified mini-split heat pump models (-1.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.0 SEER2. Closest same-cohort alternatives include ACD PUD12KCH24S-O.
Where is AC PRO.COM AWH12AGCXD-A3DNA1A/O compliant for 2026 US installation?
AC PRO.COM AWH12AGCXD-A3DNA1A/O: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does AC PRO.COM AWH12AGCXD-A3DNA1A/O model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, AC PRO.COM AWH12AGCXD-A3DNA1A/O runs 500 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does AC PRO.COM AWH12AGCXD-A3DNA1A/O cover?
AC PRO.COM AWH12AGCXD-A3DNA1A/O covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does AC PRO.COM AWH12AGCXD-A3DNA1A/O handle extreme weather or cold snaps?
Yes, AC PRO.COM AWH12AGCXD-A3DNA1A/O carries ENERGY STAR Cold Climate certification (73.3% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern AC PRO.COM AWH12AGCXD-A3DNA1A/O?
AC PRO.COM AWH12AGCXD-A3DNA1A/O specifies R-410A compliance (PD ID 2415288); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in AC PRO.COM AWH12AGCXD-A3DNA1A/O reach 24.0 SEER2?
Peak 24.0 SEER2 represents the top tested AHRI pairing for AC PRO.COM AWH12AGCXD-A3DNA1A/O (PD ID 2415288); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to AC PRO.COM AWH12AGCXD-A3DNA1A/O?
AC PRO.COM AWH12AGCXD-A3DNA1A/O requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACD PUD12KCH24S-O.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.