Air-Source Heat Pump · Tempstar · 13 ENERGY STAR Combinations

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) — Air-Source Heat Pump Specifications

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) (Air-Source Heat Pump, PD ID 4012427) holds 13 ENERGY STAR certified SKUs rated at 21.5 SEER2 — #557 of 586 (30 tied at floor), -0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) — Air-Source Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 21.5 SEER2 and Heating Rating set at 9.5 HSPF2.

Max SEER2
21.5 SEER2
Heating Rating
9.5 HSPF2
Heating COP
2.0 COP
Cohort Rank
#557/586
Verified Combos
13 SKUs
Sample PD ID
4012427
Air-Source Heat Pump Efficiency Spread across 586 certified series (21.5 to 25.0 SEER2)
Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) Air-Source Heat Pump Efficiency Spread Distribution Distribution of 586 certified series from 21.5 to 25.0 SEER2. Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) sits at 21.5 SEER2; typical midpoint is 22.0 SEER2. 33 21.5 407 21.9 88 22.3 54 22.7 1 23.1 0 23.4 2 23.8 0 24.2 1 24.6 Median 22.0 SEER2 This model: 21.5 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
21.5 - 21.9 SEER233This series
21.9 - 22.3 SEER2407Peer range
22.3 - 22.7 SEER288Peer range
22.7 - 23.1 SEER254Peer range
23.1 - 23.4 SEER21Peer range
23.4 - 23.8 SEER20Peer range
23.8 - 24.2 SEER22Peer range
24.2 - 24.6 SEER20Peer range
24.6 - 25.0 SEER21Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) residential equipment inspection. ThermalSpec Editorial Photography

How does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) rank across federal compliance and ENERGY STAR cohorts?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) ties with 29 peers at 21.5 SEER2 (the cohort floor across 586 certified series) for Max SEER2 (-0.50 SEER2 vs 22.0 SEER2 category median) across 13 certified SKU combinations. Rated for cold-climate output (75.9% capacity retention at 5F) (3.8 nominal Tons at 45,500 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) Cohort Metrics vs. Air-Source Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #557 of 586 (30 tied at floor) -0.50 SEER2 vs 22.0 SEER2 category median
Heating HSPF2 vs Cohort 9.5 HSPF2 +0.50 HSPF2 vs 9.0 HSPF2 median
Peak 95F EER2 vs Cohort 11.5 EER2 -1.00 EER2 vs 12.5 EER2 median
5F Cold-Weather Capacity Retention 75.9% of 47F rating 5F COP 2.0
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 21.5 SEER2 / 9.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 11.5 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (580/586 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) estimates reflect 13 certified SKU combinations tested under PD ID 4012427.

Cool_kWh = (45,500 BTU/h * 1,000 hrs / 21.5 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy2,116 kWh/yr$346/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,158 kWh/yr$516/yr at US median
Combined Annual Electricity Cost$861/yrState range: $671 (NV) to $2,488 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,908 kWh/yr$312/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T)?

Showing 13 certified indoor-outdoor coil combinations from 13 total AHRI matched records filed for Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) (PD ID 4012427).

T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M21A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M24A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M21A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M21A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2
T5H3V48*K*AAA* EA*5X61M21A*+WALLCON 45,500 BTU/h 21.5 SEER2 / 9.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T), review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T): headline Max SEER2 reflects peak tested matches among 13 SKUs, not lower-rated sizes.
  • Catalog specs for Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) fitSingle-family replacement needing documented ENERGY STAR PD ID 4012427 with matching indoor air handler.
Skip Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable air-source heat pump models deliver similar efficiency?

Compare Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) against Kenmore (C,H,T)5H3V48*K*AAA* (EA*5X61M 3.8T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.

Kenmore (C,H,T)5H3V48*K*AAA* (EA*5X61M 3.8T)

21.5 SEER2 · 9.5 HSPF2 · 45,500 BTU/h

Kenmore B5H3V48*K*AAA* (EA*5X61M 3.8T)

21.5 SEER2 · 9.0 HSPF2 · 45,500 BTU/h

Kenmore (C,H,T)5H3V48*K*AAA* (EA*5X60M 3.8T)

21.5 SEER2 · 9.5 HSPF2 · 45,000 BTU/h

Kenmore B5H3V48*K*AAA* (EA*5X60M 3.8T)

21.5 SEER2 · 9.0 HSPF2 · 45,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) compare with peer Air-Source Heat Pump units?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) holds #557 of 586 (30 tied at floor) out of 586 verified air-source heat pump models (-0.50 SEER2 vs 22.0 SEER2 category median), spanning 13 certified SKUs up to 21.5 SEER2. Closest same-cohort alternatives include Kenmore (C,H,T)5H3V48*K*AAA* (EA*5X61M 3.8T).

DOE Regions

Where is Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) compliant for 2026 US installation?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) runs 2,116 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) cover?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) covers 45,500-45,500 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) handle extreme weather or cold snaps?

Yes, Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) carries ENERGY STAR Cold Climate certification (75.9% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T)?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) specifies R-454B compliance (PD ID 4012427); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 13 certified SKUs in Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) reach 21.5 SEER2?

Peak 21.5 SEER2 represents the top tested AHRI pairing for Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) (PD ID 4012427); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T)?

Tempstar T5H3V48*K*AAA* (EA*5X61M 3.8T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Kenmore (C,H,T)5H3V48*K*AAA* (EA*5X61M 3.8T).

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)