Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) — Air-Source Heat Pump Specifications
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) (Air-Source Heat Pump, PD ID 3734102) holds 4 ENERGY STAR certified SKUs rated at 21.5 SEER2 — #557 of 586 (30 tied at floor), -0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) — Air-Source Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 21.5 SEER2 and Heating Rating set at 8.5 HSPF2.
- Max SEER2
- 21.5 SEER2
- Heating Rating
- 8.5 HSPF2
- Heating COP
- 2.02 COP
- Cohort Rank
- #557/586
- Verified Combos
- 4 SKUs
- Sample PD ID
- 3734102
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | This series |
| 21.9 - 22.3 SEER2 | 407 | Peer range |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) rank across federal compliance and ENERGY STAR cohorts?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) ties with 29 peers at 21.5 SEER2 (the cohort floor across 586 certified series) for Max SEER2 (-0.50 SEER2 vs 22.0 SEER2 category median) across 4 certified SKU combinations. Rated for cold-climate output (75.3% capacity retention at 5F) (3.0 nominal Tons at 35,400 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #557 of 586 (30 tied at floor) | -0.50 SEER2 vs 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 8.5 HSPF2 | -0.50 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.0 EER2 | -0.50 EER2 vs 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 75.3% of 47F rating | 5F COP 2.02 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 21.5 SEER2 / 8.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) estimates reflect 4 certified SKU combinations tested under PD ID 3734102.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,647 kWh/yr | $269/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,529 kWh/yr | $576/yr at US median |
| Combined Annual Electricity Cost | $845/yr | State range: $658 (NV) to $2,442 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,300 kWh/yr | $212/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T)?
Showing 4 certified indoor-outdoor coil combinations from 4 total AHRI matched records filed for Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) (PD ID 3734102).
| T5H3V36*K*AAA* | EVM5X44M21A*+WALLCON | 35,400 BTU/h | 21.5 SEER2 / 8.5 HSPF2 |
| T5H3V36*K*AAA* | EVM5X44M21A*+WALLCON | 35,400 BTU/h | 21.5 SEER2 / 8.5 HSPF2 |
| T5H3V36*K*AAA* | EVM5X44M21A*+WALLCON | 35,400 BTU/h | 21.5 SEER2 / 8.5 HSPF2 |
| T5H3V36*K*AAA* | EVM5X44M21A*+WALLCON | 35,400 BTU/h | 21.5 SEER2 / 8.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T): headline Max SEER2 reflects peak tested matches among 4 SKUs, not lower-rated sizes.
- Catalog specs for Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) fit | Single-family replacement needing documented ENERGY STAR PD ID 3734102 with matching indoor air handler. |
| Skip Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) against Kenmore (C,H,T)5H3V36*K*AAA* (EVM5X44M 3.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) compare with peer Air-Source Heat Pump units?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) holds #557 of 586 (30 tied at floor) out of 586 verified air-source heat pump models (-0.50 SEER2 vs 22.0 SEER2 category median), spanning 4 certified SKUs up to 21.5 SEER2. Closest same-cohort alternatives include Kenmore (C,H,T)5H3V36*K*AAA* (EVM5X44M 3.0T).
Where is Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) compliant for 2026 US installation?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) runs 1,647 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) cover?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) covers 35,400-35,400 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) handle extreme weather or cold snaps?
Yes, Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) carries ENERGY STAR Cold Climate certification (75.3% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T)?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) specifies R-454B compliance (PD ID 3734102); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 4 certified SKUs in Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) reach 21.5 SEER2?
Peak 21.5 SEER2 represents the top tested AHRI pairing for Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) (PD ID 3734102); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T)?
Tempstar T5H3V36*K*AAA* (EVM5X44M 3.0T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Kenmore (C,H,T)5H3V36*K*AAA* (EVM5X44M 3.0T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages