Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) — Air-Source Heat Pump Specifications
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) (Air-Source Heat Pump, PD ID 4606785) holds 4 ENERGY STAR certified SKUs rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).
- Max SEER2
- 22.0 SEER2
- Heating Rating
- 8.5 HSPF2
- Heating COP
- 2.06 COP
- Cohort Rank
- #147/586
- Verified Combos
- 4 SKUs
- Sample PD ID
- 4606785
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | This series |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) rank across federal compliance and ENERGY STAR cohorts?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 4 certified SKU combinations. Rated for cold-climate output (74.7% capacity retention at 5F) (3.0 nominal Tons at 35,400 BTU/h) charged with R-454B.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #147 of 586 (407 tied at median) | Equal to 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 8.5 HSPF2 | -0.50 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.5 EER2 | Equal to 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 74.7% of 47F rating | 5F COP 2.06 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 8.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) require?
Modeled utility figures for Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) (Keeprite) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,609 kWh/yr | $263/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,529 kWh/yr | $576/yr at US median |
| Combined Annual Electricity Cost | $839/yr | State range: $654 (NV) to $2,424 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,338 kWh/yr | $218/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T)?
Showing 4 certified indoor-outdoor coil combinations from 4 total AHRI matched records filed for Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) (PD ID 4606785).
| B5H3V36*K*AAA* | EVD5X49M24A*+WALLCON | 35,400 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| B5H3V36*K*AAA* | EVD5X49M24A*+WALLCON | 35,400 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| B5H3V36*K*AAA* | EVD5X49M24A*+WALLCON | 35,400 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| B5H3V36*K*AAA* | EVD5X49M24A*+WALLCON | 35,400 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T): headline Max SEER2 reflects peak tested matches among 4 SKUs, not lower-rated sizes.
- Catalog specs for Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) fit | Single-family replacement needing documented ENERGY STAR PD ID 4606785 with matching indoor air handler. |
| Skip Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) against Arcoaire H5H3V36*K*AAA* (EVD5X60M 3.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) compare with peer Air-Source Heat Pump units?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 4 certified SKUs up to 22.0 SEER2. Closest same-cohort alternatives include Arcoaire H5H3V36*K*AAA* (EVD5X60M 3.0T).
Where is Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) compliant for 2026 US installation?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) runs 1,609 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) cover?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) covers 35,400-35,400 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) handle extreme weather or cold snaps?
Yes, Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) carries ENERGY STAR Cold Climate certification (74.7% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T)?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) specifies R-454B compliance (PD ID 4606785); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 4 certified SKUs in Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) reach 22.0 SEER2?
Peak 22.0 SEER2 represents the top tested AHRI pairing for Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) (PD ID 4606785); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T)?
Keeprite B5H3V36*K*AAA* (EVD5X49M 3.0T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Arcoaire H5H3V36*K*AAA* (EVD5X60M 3.0T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.