Johnson Controls XH960E2C11 (CTF60C5C 4.0T) — Air-Source Heat Pump Specifications
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) (Air-Source Heat Pump, PD ID 4519041) holds 1 ENERGY STAR certified SKU rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).
- Max SEER2
- 22.0 SEER2
- Heating Rating
- 8.5 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #147/586
- Verified Combos
- 1 SKU
- Sample PD ID
- 4519041
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | This series |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) rank across federal compliance and ENERGY STAR cohorts?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (92.7% capacity retention at 5F) (4.0 nominal Tons at 48,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #147 of 586 (407 tied at median) | Equal to 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 8.5 HSPF2 | -0.50 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 11.7 EER2 | -0.80 EER2 vs 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 92.7% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 8.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 11.7 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) require?
Modeled utility figures for Johnson Controls XH960E2C11 (CTF60C5C 4.0T) (Johnson Controls) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 2,182 kWh/yr | $356/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,529 kWh/yr | $576/yr at US median |
| Combined Annual Electricity Cost | $933/yr | State range: $726 (NV) to $2,694 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,646 kWh/yr | $269/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Johnson Controls XH960E2C11 (CTF60C5C 4.0T)?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Johnson Controls XH960E2C11 (CTF60C5C 4.0T) (PD ID 4519041).
| XH960E2C11 | CTF60C5CGS1+JMC17C2SN1+CC | 48,000 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Johnson Controls XH960E2C11 (CTF60C5C 4.0T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Johnson Controls XH960E2C11 (CTF60C5C 4.0T): headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Johnson Controls XH960E2C11 (CTF60C5C 4.0T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Johnson Controls XH960E2C11 (CTF60C5C 4.0T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Johnson Controls XH960E2C11 (CTF60C5C 4.0T) fit | Single-family replacement needing documented ENERGY STAR PD ID 4519041 with matching indoor air handler. |
| Skip Johnson Controls XH960E2C11 (CTF60C5C 4.0T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare Johnson Controls XH960E2C11 (CTF60C5C 4.0T) against CHAMPION HEATING AND COOLING XH960E2C11 (CTF60C5C 4.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) compare with peer Air-Source Heat Pump units?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 1 certified SKU up to 22.0 SEER2. Closest same-cohort alternatives include CHAMPION HEATING AND COOLING XH960E2C11 (CTF60C5C 4.0T).
Where is Johnson Controls XH960E2C11 (CTF60C5C 4.0T) compliant for 2026 US installation?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Johnson Controls XH960E2C11 (CTF60C5C 4.0T) runs 2,182 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) cover?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) covers 48,000-48,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Johnson Controls XH960E2C11 (CTF60C5C 4.0T) handle extreme weather or cold snaps?
Yes, Johnson Controls XH960E2C11 (CTF60C5C 4.0T) carries ENERGY STAR Cold Climate certification (92.7% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Johnson Controls XH960E2C11 (CTF60C5C 4.0T)?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) specifies R-454B compliance (PD ID 4519041); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Johnson Controls XH960E2C11 (CTF60C5C 4.0T) reach 22.0 SEER2?
Peak 22.0 SEER2 represents the top tested AHRI pairing for Johnson Controls XH960E2C11 (CTF60C5C 4.0T) (PD ID 4519041); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Johnson Controls XH960E2C11 (CTF60C5C 4.0T)?
Johnson Controls XH960E2C11 (CTF60C5C 4.0T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include CHAMPION HEATING AND COOLING XH960E2C11 (CTF60C5C 4.0T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)