BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) — Air-Source Heat Pump Specifications
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) (Air-Source Heat Pump, PD ID 3727997) holds 9 ENERGY STAR certified SKUs rated at 22.5 SEER2 — #59 of 586 (Top 24.2%, 84 tied), +0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).
- Max SEER2
- 22.5 SEER2
- Heating Rating
- 8.5 HSPF2
- Heating COP
- 2.06 COP
- Cohort Rank
- #59/586
- Verified Combos
- 9 SKUs
- Sample PD ID
- 3727997
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | Peer range |
| 22.3 - 22.7 SEER2 | 88 | This series |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) rank across federal compliance and ENERGY STAR cohorts?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) ranks #59 of 586 (tied with 83 others at 22.5 SEER2, top 24.2%, more efficient than 75.8% of certified series) for Max SEER2 (+0.50 SEER2 vs 22.0 SEER2 category median) across 9 certified SKU combinations. Rated for cold-climate output (76.2% capacity retention at 5F) (3.0 nominal Tons at 36,000 BTU/h) charged with R-454B.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #59 of 586 (Top 24.2%, 84 tied) | +0.50 SEER2 vs 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 8.5 HSPF2 | -0.50 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.5 EER2 | Equal to 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 76.2% of 47F rating | 5F COP 2.06 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.5 SEER2 / 8.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) require?
Modeled utility figures for BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) (BRYANT HEATING AND COOLING SYSTEMS) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,600 kWh/yr | $261/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,529 kWh/yr | $576/yr at US median |
| Combined Annual Electricity Cost | $838/yr | State range: $652 (NV) to $2,420 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,388 kWh/yr | $227/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T)?
Showing 9 certified indoor-outdoor coil combinations from 9 total AHRI matched records filed for BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) (PD ID 3727997).
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.5 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.5 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.5 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.5 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 35,800 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
| 293VAN036**AA* | CVAMA6124XMA*+UI | 36,000 BTU/h | 22.0 SEER2 / 8.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T): headline Max SEER2 reflects peak tested matches among 9 SKUs, not lower-rated sizes.
- Catalog specs for BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) fit | Single-family replacement needing documented ENERGY STAR PD ID 3727997 with matching indoor air handler. |
| Skip BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) against ACIQ B5H3V36*K*AAA* (EVD5X61M 3.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) compare with peer Air-Source Heat Pump units?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) holds #59 of 586 (Top 24.2%, 84 tied) out of 586 verified air-source heat pump models (+0.50 SEER2 vs 22.0 SEER2 category median), spanning 9 certified SKUs up to 22.5 SEER2. Closest same-cohort alternatives include ACIQ B5H3V36*K*AAA* (EVD5X61M 3.0T).
Where is BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) compliant for 2026 US installation?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) runs 1,600 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) cover?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) covers 35,800-36,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) handle extreme weather or cold snaps?
Yes, BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) carries ENERGY STAR Cold Climate certification (76.2% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T)?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) specifies R-454B compliance (PD ID 3727997); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 9 certified SKUs in BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) reach 22.5 SEER2?
Peak 22.5 SEER2 represents the top tested AHRI pairing for BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) (PD ID 3727997); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T)?
BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAMA612 3.0T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ B5H3V36*K*AAA* (EVD5X61M 3.0T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)