BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) — Air-Source Heat Pump Specifications
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) (Air-Source Heat Pump, PD ID 4499761) holds 2 ENERGY STAR certified SKUs rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).
- Max SEER2
- 22.0 SEER2
- Heating Rating
- 9.5 HSPF2
- Heating COP
- 2.1 COP
- Cohort Rank
- #147/586
- Verified Combos
- 2 SKUs
- Sample PD ID
- 4499761
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | This series |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) rank across federal compliance and ENERGY STAR cohorts?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (81.0% capacity retention at 5F) (1.9 nominal Tons at 23,200 BTU/h) charged with R-454B.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #147 of 586 (407 tied at median) | Equal to 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 9.5 HSPF2 | +0.50 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.0 EER2 | +0.50 EER2 vs 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 81.0% of 47F rating | 5F COP 2.1 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 9.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) require?
Modeled utility figures for BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) (BRYANT HEATING AND COOLING SYSTEMS) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,055 kWh/yr | $172/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,158 kWh/yr | $516/yr at US median |
| Combined Annual Electricity Cost | $688/yr | State range: $536 (NV) to $1,988 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,409 kWh/yr | $230/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T)?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) (PD ID 4499761).
| 293VAN024**AA* | CVAVA3617XMA*+UI | 23,200 BTU/h | 22.0 SEER2 / 9.5 HSPF2 |
| 293VAN024**AA* | CVAVA3617XMA*+UI | 23,200 BTU/h | 22.0 SEER2 / 9.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T): headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) fit | Single-family replacement needing documented ENERGY STAR PD ID 4499761 with matching indoor air handler. |
| Skip BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) against ACIQ B5H3V24*K*AAA* (EVD5X25M 1.9T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) compare with peer Air-Source Heat Pump units?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 2 certified SKUs up to 22.0 SEER2. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X25M 1.9T).
Where is BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) compliant for 2026 US installation?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) runs 1,055 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) cover?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) covers 23,200-23,200 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) handle extreme weather or cold snaps?
Yes, BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) carries ENERGY STAR Cold Climate certification (81.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T)?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) specifies R-454B compliance (PD ID 4499761); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) reach 22.0 SEER2?
Peak 22.0 SEER2 represents the top tested AHRI pairing for BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) (PD ID 4499761); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T)?
BRYANT HEATING AND COOLING SYSTEMS 293VAN024**AA* (CVAVA361 1.9T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X25M 1.9T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)