Atomi Smart AT2239 CA — Air-Source Heat Pump Specifications
Atomi Smart AT2239 CA (Air-Source Heat Pump, PD ID 3999511) holds 1 ENERGY STAR certified SKU rated at 23.9 SEER2 — #2 of 586 (Top 0.5%, 2 tied), +1.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Atomi Smart AT2239 CA — Air-Source Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.9 SEER2 and Heating Rating set at 8.25 HSPF2.
- Max SEER2
- 23.9 SEER2
- Heating Rating
- 8.25 HSPF2
- Cohort Rank
- #2/586
- Verified Combos
- 1 SKU
- Sample PD ID
- 3999511
- Federal AC Minimum
- 13.4 - 14.3 SEER2
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | Peer range |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | This series |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does Atomi Smart AT2239 CA rank across federal compliance and ENERGY STAR cohorts?
Atomi Smart AT2239 CA ranks #2 of 586 (tied with 1 other at 23.9 SEER2, top 0.5%, more efficient than 99.5% of certified series) for Max SEER2 (+1.90 SEER2 vs 22.0 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (1.0 nominal Tons at 12,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2 of 586 (Top 0.5%, 2 tied) | +1.90 SEER2 vs 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 8.25 HSPF2 | -0.75 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.05 EER2 | +0.55 EER2 vs 12.5 EER2 median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.9 SEER2 / 8.25 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.05 EER2 |
| ENERGY STAR Cold Climate Spec | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Atomi Smart AT2239 CA require?
Modeled utility figures for Atomi Smart AT2239 CA (Atomi Smart) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 502 kWh/yr | $82/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,636 kWh/yr | $594/yr at US median |
| Combined Annual Electricity Cost | $676/yr | State range: $526 (NV) to $1,952 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 701 kWh/yr | $114/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Atomi Smart AT2239 CA?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Atomi Smart AT2239 CA (PD ID 3999511).
| AT2239 CA | Matched AHRI Coil | 12,000 BTU/h | 23.9 SEER2 / 8.2 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Atomi Smart AT2239 CA, review 4 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Atomi Smart AT2239 CA: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Atomi Smart AT2239 CA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Atomi Smart AT2239 CA lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
- Atomi Smart AT2239 CA uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Atomi Smart AT2239 CA fit | Single-family replacement needing documented ENERGY STAR PD ID 3999511 with matching indoor air handler. |
| Skip Atomi Smart AT2239 CA if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare Atomi Smart AT2239 CA against Atomi Smart AT2239 and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Atomi Smart AT2239 CA compare with peer Air-Source Heat Pump units?
Atomi Smart AT2239 CA holds #2 of 586 (Top 0.5%, 2 tied) out of 586 verified air-source heat pump models (+1.90 SEER2 vs 22.0 SEER2 category median), spanning 1 certified SKU up to 23.9 SEER2. Closest same-cohort alternatives include Atomi Smart AT2239.
Where is Atomi Smart AT2239 CA compliant for 2026 US installation?
Atomi Smart AT2239 CA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Atomi Smart AT2239 CA model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Atomi Smart AT2239 CA runs 502 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Atomi Smart AT2239 CA cover?
Atomi Smart AT2239 CA covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Atomi Smart AT2239 CA handle extreme weather or cold snaps?
Atomi Smart AT2239 CA is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Atomi Smart AT2239 CA?
Atomi Smart AT2239 CA specifies R-32 compliance (PD ID 3999511); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Atomi Smart AT2239 CA reach 23.9 SEER2?
Peak 23.9 SEER2 represents the top tested AHRI pairing for Atomi Smart AT2239 CA (PD ID 3999511); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Atomi Smart AT2239 CA?
Atomi Smart AT2239 CA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Atomi Smart AT2239.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.