American Standard 5A6V0X24A1 (5PX*B006 1.8T) — Air-Source Heat Pump Specifications
American Standard 5A6V0X24A1 (5PX*B006 1.8T) (Air-Source Heat Pump, PD ID 4529513) holds 1 ENERGY STAR certified SKU rated at 21.8 SEER2 — #554 of 586 (2 tied, beats 5.3% of peers), -0.20 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). American Standard 5A6V0X24A1 (5PX*B006 1.8T) — Air-Source Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 21.8 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 21.8 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.1 COP
- Cohort Rank
- #554/586
- Verified Combos
- 1 SKU
- Sample PD ID
- 4529513
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | This series |
| 21.9 - 22.3 SEER2 | 407 | Peer range |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |
How does American Standard 5A6V0X24A1 (5PX*B006 1.8T) rank across federal compliance and ENERGY STAR cohorts?
American Standard 5A6V0X24A1 (5PX*B006 1.8T) ranks #554 of 586 (tied with 1 other at 21.8 SEER2, more efficient than 5.3% of certified series) for Max SEER2 (-0.20 SEER2 vs 22.0 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (75.0% capacity retention at 5F) (1.8 nominal Tons at 21,200 BTU/h) charged with R-454B.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #554 of 586 (2 tied, beats 5.3% of peers) | -0.20 SEER2 vs 22.0 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | +1.00 HSPF2 vs 9.0 HSPF2 median |
| Peak 95F EER2 vs Cohort | 11.7 EER2 | -0.80 EER2 vs 12.5 EER2 median |
| 5F Cold-Weather Capacity Retention | 75.0% of 47F rating | 5F COP 2.1 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 21.8 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 11.7 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (580/586 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does American Standard 5A6V0X24A1 (5PX*B006 1.8T) require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, American Standard 5A6V0X24A1 (5PX*B006 1.8T) estimates reflect 1 certified SKU combination tested under PD ID 4529513.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 972 kWh/yr | $159/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $649/yr | State range: $505 (NV) to $1,874 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,511 kWh/yr | $247/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to American Standard 5A6V0X24A1 (5PX*B006 1.8T)?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for American Standard 5A6V0X24A1 (5PX*B006 1.8T) (PD ID 4529513).
| 5A6V0X24A1 | 5PX*B006AS3 | 21,200 BTU/h | 21.8 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on American Standard 5A6V0X24A1 (5PX*B006 1.8T), review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across American Standard 5A6V0X24A1 (5PX*B006 1.8T): headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for American Standard 5A6V0X24A1 (5PX*B006 1.8T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- American Standard 5A6V0X24A1 (5PX*B006 1.8T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal American Standard 5A6V0X24A1 (5PX*B006 1.8T) fit | Single-family replacement needing documented ENERGY STAR PD ID 4529513 with matching indoor air handler. |
| Skip American Standard 5A6V0X24A1 (5PX*B006 1.8T) if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable air-source heat pump models deliver similar efficiency?
Compare American Standard 5A6V0X24A1 (5PX*B006 1.8T) against Trane 5TWV0X24A1 (5PX*B006 1.8T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does American Standard 5A6V0X24A1 (5PX*B006 1.8T) compare with peer Air-Source Heat Pump units?
American Standard 5A6V0X24A1 (5PX*B006 1.8T) holds #554 of 586 (2 tied, beats 5.3% of peers) out of 586 verified air-source heat pump models (-0.20 SEER2 vs 22.0 SEER2 category median), spanning 1 certified SKU up to 21.8 SEER2. Closest same-cohort alternatives include Trane 5TWV0X24A1 (5PX*B006 1.8T).
Where is American Standard 5A6V0X24A1 (5PX*B006 1.8T) compliant for 2026 US installation?
American Standard 5A6V0X24A1 (5PX*B006 1.8T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does American Standard 5A6V0X24A1 (5PX*B006 1.8T) model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, American Standard 5A6V0X24A1 (5PX*B006 1.8T) runs 972 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does American Standard 5A6V0X24A1 (5PX*B006 1.8T) cover?
American Standard 5A6V0X24A1 (5PX*B006 1.8T) covers 21,200-21,200 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does American Standard 5A6V0X24A1 (5PX*B006 1.8T) handle extreme weather or cold snaps?
Yes, American Standard 5A6V0X24A1 (5PX*B006 1.8T) carries ENERGY STAR Cold Climate certification (75.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern American Standard 5A6V0X24A1 (5PX*B006 1.8T)?
American Standard 5A6V0X24A1 (5PX*B006 1.8T) specifies R-454B compliance (PD ID 4529513); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in American Standard 5A6V0X24A1 (5PX*B006 1.8T) reach 21.8 SEER2?
Peak 21.8 SEER2 represents the top tested AHRI pairing for American Standard 5A6V0X24A1 (5PX*B006 1.8T) (PD ID 4529513); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to American Standard 5A6V0X24A1 (5PX*B006 1.8T)?
American Standard 5A6V0X24A1 (5PX*B006 1.8T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Trane 5TWV0X24A1 (5PX*B006 1.8T).
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)