Skip to main content
Geothermal Heat Pump · WATERLESS · 1 ENERGY STAR Combinations

WATERLESS WG2AD-60D1-CP*-*-* — Geothermal Heat Pump Specifications

WATERLESS WG2AD-60D1-CP*-*-* (Geothermal Heat Pump, PD ID 3999538) holds 1 ENERGY STAR certified SKU rated at 4.3 COP — #1,174 of 1,730 (194 tied, beats 21% of peers), -0.20 COP. ENERGY STAR certified residential HVAC model. WATERLESS WG2AD-60D1-CP*-*-* — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.3 COP and Cohort Rank set at #1,174/1,730.

Heating COP
4.3 COP
Cohort Rank
#1,174/1,730
Verified Combos
1 SKU
Sample PD ID
3999538
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
WATERLESS WG2AD-60D1-CP*-*-* Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. WATERLESS WG2AD-60D1-CP*-*-* sits at 4.3 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.3 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329This series
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
WATERLESS WG2AD-60D1-CP*-*-* residential equipment inspection. ThermalSpec Editorial Photography

How does WATERLESS WG2AD-60D1-CP*-*-* rank across federal compliance and ENERGY STAR cohorts?

WATERLESS WG2AD-60D1-CP*-*-* ranks #1,174 of 1,730 (tied with 193 others at 4.30 COP, more efficient than 21% of certified series) for Max COP (-0.20 COP vs 4.50 COP category median) across 1 certified SKU combination. DGX-to-Air unit delivering 4.3 COP and 22.5 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match WATERLESS in ThermalSpec's current SaferProducts feed.

WATERLESS WG2AD-60D1-CP*-*-* Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #1,174 of 1,730 (194 tied, beats 21% of peers) -0.20 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 22.5 EER -2.10 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.3 / Max EER 22.5 (DGX-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does WATERLESS WG2AD-60D1-CP*-*-* require?

Annual cost outputs combine WATERLESS WG2AD-60D1-CP*-*-*'s 4.3 COP rating and EIA national tariffs across single-family runtime hours.

Heat_kWh = 50,000 kBTU / (4.3 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (22.5 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,408 kWh/yr$557/yr
Ground-Source Cooling Electricity (1,000 hrs)1,600 kWh/yr$261/yr
Total Annual Geothermal Operating Cost$818/yrState range: $637 to $2,363
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to WATERLESS WG2AD-60D1-CP*-*-*?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for WATERLESS WG2AD-60D1-CP*-*-* (PD ID 3999538).

WG2AD-60D1-CP*-*-* Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on WATERLESS WG2AD-60D1-CP*-*-*, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across WATERLESS WG2AD-60D1-CP*-*-*: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for WATERLESS WG2AD-60D1-CP*-*-* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal WATERLESS WG2AD-60D1-CP*-*-* fitSingle-family replacement needing documented ENERGY STAR PD ID 3999538 with matching indoor air handler.
Skip WATERLESS WG2AD-60D1-CP*-*-* ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare WATERLESS WG2AD-60D1-CP*-*-* against Heil HS036***N***1**2 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Heil HS036***N***1**2

4.3 COP · 23.1 EER · 2 combos

Hydron Module HBT072

4.3 COP · 23.4 EER · 2 combos

Hydron Module HVS012

4.3 COP · 24.1 EER · 1 combos

Hydron Module HVS060

4.3 COP · 21.3 EER · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does WATERLESS WG2AD-60D1-CP*-*-* compare with peer Geothermal Heat Pump units?

WATERLESS WG2AD-60D1-CP*-*-* holds #1,174 of 1,730 (194 tied, beats 21% of peers) out of 1,730 verified geothermal heat pump models (-0.20 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.3 COP. Closest same-cohort alternatives include Heil HS036***N***1**2.

DOE Regions

Where is WATERLESS WG2AD-60D1-CP*-*-* compliant for 2026 US installation?

WATERLESS WG2AD-60D1-CP*-*-*: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does WATERLESS WG2AD-60D1-CP*-*-* model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, WATERLESS WG2AD-60D1-CP*-*-* runs 3,408 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does WATERLESS WG2AD-60D1-CP*-*-* cover?

WATERLESS WG2AD-60D1-CP*-*-* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does WATERLESS WG2AD-60D1-CP*-*-* handle extreme weather or cold snaps?

WATERLESS WG2AD-60D1-CP*-*-* is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern WATERLESS WG2AD-60D1-CP*-*-*?

WATERLESS WG2AD-60D1-CP*-*-* specifies Other compliance (PD ID 3999538); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in WATERLESS WG2AD-60D1-CP*-*-* reach 4.3 COP?

Peak 4.3 COP represents the top tested AHRI pairing for WATERLESS WG2AD-60D1-CP*-*-* (PD ID 3999538); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to WATERLESS WG2AD-60D1-CP*-*-*?

WATERLESS WG2AD-60D1-CP*-*-* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Heil HS036***N***1**2.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros