TETCO TYT072 — Geothermal Heat Pump Specifications
TETCO TYT072 (Geothermal Heat Pump, PD ID 2545458) holds 2 ENERGY STAR certified SKUs rated at 4.7 COP — #471 of 1,730 (Top 36.2%, 156 tied), +0.20 COP. ENERGY STAR certified residential HVAC model. TETCO TYT072 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.7 COP and Cohort Rank set at #471/1,730.
- Heating COP
- 4.7 COP
- Cohort Rank
- #471/1,730
- Verified Combos
- 2 SKUs
- Sample PD ID
- 2545458
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | This series |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does TETCO TYT072 rank across federal compliance and ENERGY STAR cohorts?
TETCO TYT072 ranks #471 of 1,730 (tied with 155 others at 4.70 COP, top 36.2%, more efficient than 63.8% of certified series) for Max COP (+0.20 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.7 COP and 26.4 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match TETCO in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #471 of 1,730 (Top 36.2%, 156 tied) | +0.20 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 26.4 EER | +1.80 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.7 / Max EER 26.4 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does TETCO TYT072 require?
Annual cost outputs combine TETCO TYT072's 4.7 COP rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,118 kWh/yr | $509/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,364 kWh/yr | $223/yr |
| Total Annual Geothermal Operating Cost | $732/yr | State range: $570 to $2,115 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to TETCO TYT072?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for TETCO TYT072 (PD ID 2545458).
| TYT072 | Matched AHRI Coil | — | |
| TYT072 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on TETCO TYT072, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across TETCO TYT072: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for TETCO TYT072 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal TETCO TYT072 fit | Single-family replacement needing documented ENERGY STAR PD ID 2545458 with matching indoor air handler. |
| Skip TETCO TYT072 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare TETCO TYT072 against GeoSmart Energy GTZ038*1*J and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does TETCO TYT072 compare with peer Geothermal Heat Pump units?
TETCO TYT072 holds #471 of 1,730 (Top 36.2%, 156 tied) out of 1,730 verified geothermal heat pump models (+0.20 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 4.7 COP. Closest same-cohort alternatives include GeoSmart Energy GTZ038*1*J.
Where is TETCO TYT072 compliant for 2026 US installation?
TETCO TYT072: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does TETCO TYT072 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, TETCO TYT072 runs 3,118 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does TETCO TYT072 cover?
TETCO TYT072 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does TETCO TYT072 handle extreme weather or cold snaps?
TETCO TYT072 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern TETCO TYT072?
TETCO TYT072 specifies R-410A compliance (PD ID 2545458); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in TETCO TYT072 reach 4.7 COP?
Peak 4.7 COP represents the top tested AHRI pairing for TETCO TYT072 (PD ID 2545458); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to TETCO TYT072?
TETCO TYT072 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GeoSmart Energy GTZ038*1*J.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.