TETCO TVS006 — Geothermal Heat Pump Specifications
TETCO TVS006 (Geothermal Heat Pump, PD ID 2635490) holds 1 ENERGY STAR certified SKU rated at 4.6 COP — #627 of 1,730 (Top 45.6%, 163 tied), +0.10 COP. ENERGY STAR certified residential HVAC model. TETCO TVS006 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.6 COP and Cohort Rank set at #627/1,730.
- Heating COP
- 4.6 COP
- Cohort Rank
- #627/1,730
- Verified Combos
- 1 SKU
- Sample PD ID
- 2635490
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | This series |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does TETCO TVS006 rank across federal compliance and ENERGY STAR cohorts?
TETCO TVS006 ranks #627 of 1,730 (tied with 162 others at 4.60 COP, top 45.6%, more efficient than 54.4% of certified series) for Max COP (+0.10 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.6 COP and 25.8 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match TETCO in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #627 of 1,730 (Top 45.6%, 163 tied) | +0.10 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 25.8 EER | +1.20 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.6 / Max EER 25.8 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does TETCO TVS006 require?
Modeled utility figures for TETCO TVS006 (TETCO) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,186 kWh/yr | $520/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,395 kWh/yr | $228/yr |
| Total Annual Geothermal Operating Cost | $748/yr | State range: $583 to $2,161 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to TETCO TVS006?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for TETCO TVS006 (PD ID 2635490).
| TVS006 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on TETCO TVS006, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across TETCO TVS006: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for TETCO TVS006 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal TETCO TVS006 fit | Single-family replacement needing documented ENERGY STAR PD ID 2635490 with matching indoor air handler. |
| Skip TETCO TVS006 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare TETCO TVS006 against GeoSmart Energy QT064**1*1*****J and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does TETCO TVS006 compare with peer Geothermal Heat Pump units?
TETCO TVS006 holds #627 of 1,730 (Top 45.6%, 163 tied) out of 1,730 verified geothermal heat pump models (+0.10 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.6 COP. Closest same-cohort alternatives include GeoSmart Energy QT064**1*1*****J.
Where is TETCO TVS006 compliant for 2026 US installation?
TETCO TVS006: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does TETCO TVS006 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, TETCO TVS006 runs 3,186 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does TETCO TVS006 cover?
TETCO TVS006 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does TETCO TVS006 handle extreme weather or cold snaps?
TETCO TVS006 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern TETCO TVS006?
TETCO TVS006 specifies R-410A compliance (PD ID 2635490); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in TETCO TVS006 reach 4.6 COP?
Peak 4.6 COP represents the top tested AHRI pairing for TETCO TVS006 (PD ID 2635490); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to TETCO TVS006?
TETCO TVS006 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GeoSmart Energy QT064**1*1*****J.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)