Skip to main content
Geothermal Heat Pump · TETCO · 2 ENERGY STAR Combinations

TETCO TRT036 — Geothermal Heat Pump Specifications

TETCO TRT036 (Geothermal Heat Pump, PD ID 2635606) holds 2 ENERGY STAR certified SKUs rated at 4.4 COP — #923 of 1,730 (251 tied, beats 32.2% of peers), -0.10 COP. ENERGY STAR certified residential HVAC model. TETCO TRT036 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.4 COP and Cohort Rank set at #923/1,730.

Heating COP
4.4 COP
Cohort Rank
#923/1,730
Verified Combos
2 SKUs
Sample PD ID
2635606
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
TETCO TRT036 Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. TETCO TRT036 sits at 4.4 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.4 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251This series
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
TETCO TRT036 residential equipment inspection. ThermalSpec Editorial Photography

How does TETCO TRT036 rank across federal compliance and ENERGY STAR cohorts?

TETCO TRT036 ranks #923 of 1,730 (tied with 250 others at 4.40 COP, more efficient than 32.2% of certified series) for Max COP (-0.10 COP vs 4.50 COP category median) across 2 certified SKU combinations. Closed Loop Water-to-Air unit delivering 4.4 COP and 22.9 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match TETCO in ThermalSpec's current SaferProducts feed.

TETCO TRT036 Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #923 of 1,730 (251 tied, beats 32.2% of peers) -0.10 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 22.9 EER -1.70 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.4 / Max EER 22.9 (Closed Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does TETCO TRT036 require?

Modeled utility figures for TETCO TRT036 (TETCO) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.4 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (22.9 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,330 kWh/yr$544/yr
Ground-Source Cooling Electricity (1,000 hrs)1,572 kWh/yr$257/yr
Total Annual Geothermal Operating Cost$800/yrState range: $624 to $2,313
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to TETCO TRT036?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for TETCO TRT036 (PD ID 2635606).

TRT036 Matched AHRI Coil —
TRT036 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on TETCO TRT036, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across TETCO TRT036: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for TETCO TRT036 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal TETCO TRT036 fitSingle-family replacement needing documented ENERGY STAR PD ID 2635606 with matching indoor air handler.
Skip TETCO TRT036 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare TETCO TRT036 against Heil HBR48V/H**N******1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Heil HBR48V/H**N******1

4.4 COP · 24.0 EER · 1 combos

Heil HBR60V/H**C******1

4.4 COP · 23.3 EER · 1 combos

Heil HBR60V/H**N******1

4.4 COP · 23.3 EER · 1 combos

Heil HP048V/H/C******1**1

4.4 COP · 21.5 EER · 2 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does TETCO TRT036 compare with peer Geothermal Heat Pump units?

TETCO TRT036 holds #923 of 1,730 (251 tied, beats 32.2% of peers) out of 1,730 verified geothermal heat pump models (-0.10 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 4.4 COP. Closest same-cohort alternatives include Heil HBR48V/H**N******1.

DOE Regions

Where is TETCO TRT036 compliant for 2026 US installation?

TETCO TRT036: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does TETCO TRT036 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, TETCO TRT036 runs 3,330 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does TETCO TRT036 cover?

TETCO TRT036 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does TETCO TRT036 handle extreme weather or cold snaps?

TETCO TRT036 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern TETCO TRT036?

TETCO TRT036 specifies R-410A compliance (PD ID 2635606); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in TETCO TRT036 reach 4.4 COP?

Peak 4.4 COP represents the top tested AHRI pairing for TETCO TRT036 (PD ID 2635606); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to TETCO TRT036?

TETCO TRT036 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Heil HBR48V/H**N******1.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros