Tempstar HCR24H**C******1 — Geothermal Heat Pump Specifications

Tempstar HCR24H**C******1 (Geothermal Heat Pump, PD ID 4009349) holds 2 ENERGY STAR certified SKUs rated at 4.9 COP — #281 of 1,730 (Top 22.1%, 102 tied), +0.40 COP. ENERGY STAR certified residential HVAC model. Tempstar HCR24H**C******1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.9 COP and Cohort Rank set at #281/1,730.

Heating COP
4.9 COP
Cohort Rank
#281/1,730
Verified Combos
2 SKUs
Sample PD ID
4009349
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Tempstar HCR24H**C******1 Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Tempstar HCR24H**C******1 sits at 4.9 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.9 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310This series
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Tempstar HCR24H**C******1 residential equipment inspection. ThermalSpec Editorial Photography

How does Tempstar HCR24H**C******1 rank across federal compliance and ENERGY STAR cohorts?

Tempstar HCR24H**C******1 ranks #281 of 1,730 (tied with 101 others at 4.90 COP, top 22.1%, more efficient than 77.9% of certified series) for Max COP (+0.40 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.9 COP and 27.8 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Tempstar in ThermalSpec's current SaferProducts feed.

Tempstar HCR24H**C******1 Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #281 of 1,730 (Top 22.1%, 102 tied) +0.40 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 27.8 EER +3.20 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.9 / Max EER 27.8 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does Tempstar HCR24H**C******1 require?

Modeled utility figures for Tempstar HCR24H**C******1 (Tempstar) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.9 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (27.8 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity2,991 kWh/yr$488/yr
Ground-Source Cooling Electricity (1,000 hrs)1,295 kWh/yr$211/yr
Total Annual Geothermal Operating Cost$700/yrState range: $545 to $2,022
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Tempstar HCR24H**C******1?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Tempstar HCR24H**C******1 (PD ID 4009349).

HCR24H**C******1 Matched AHRI Coil —
HCR24H**C******1 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Tempstar HCR24H**C******1, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Tempstar HCR24H**C******1: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for Tempstar HCR24H**C******1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Tempstar HCR24H**C******1 fitSingle-family replacement needing documented ENERGY STAR PD ID 4009349 with matching indoor air handler.
Skip Tempstar HCR24H**C******1 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Tempstar HCR24H**C******1 against Comfortmaker HCR24H**N******1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Comfortmaker HCR24H**N******1

4.9 COP · 27.8 EER · 2 combos

Comfortmaker HCR24V**C******1

4.9 COP · 27.8 EER · 2 combos

Comfortmaker HCR24V**N******1

4.9 COP · 27.8 EER · 2 combos

Comfortmaker HS024SR*N******1

4.9 COP · 26.8 EER · 3 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Tempstar HCR24H**C******1 compare with peer Geothermal Heat Pump units?

Tempstar HCR24H**C******1 holds #281 of 1,730 (Top 22.1%, 102 tied) out of 1,730 verified geothermal heat pump models (+0.40 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 4.9 COP. Closest same-cohort alternatives include Comfortmaker HCR24H**N******1.

DOE Regions

Where is Tempstar HCR24H**C******1 compliant for 2026 US installation?

Tempstar HCR24H**C******1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Tempstar HCR24H**C******1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Tempstar HCR24H**C******1 runs 2,991 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Tempstar HCR24H**C******1 cover?

Tempstar HCR24H**C******1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Tempstar HCR24H**C******1 handle extreme weather or cold snaps?

Tempstar HCR24H**C******1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Tempstar HCR24H**C******1?

Tempstar HCR24H**C******1 specifies Other compliance (PD ID 4009349); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in Tempstar HCR24H**C******1 reach 4.9 COP?

Peak 4.9 COP represents the top tested AHRI pairing for Tempstar HCR24H**C******1 (PD ID 4009349); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Tempstar HCR24H**C******1?

Tempstar HCR24H**C******1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Comfortmaker HCR24H**N******1.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)