Skip to main content
Geothermal Heat Pump · Keeprite · 1 ENERGY STAR Combinations

Keeprite HBR24V/H**C******1 — Geothermal Heat Pump Specifications

Keeprite HBR24V/H**C******1 (Geothermal Heat Pump, PD ID 3706876) holds 1 ENERGY STAR certified SKU rated at 4.3 COP — #1,174 of 1,730 (194 tied, beats 21% of peers), -0.20 COP. ENERGY STAR certified residential HVAC model. Keeprite HBR24V/H**C******1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.3 COP and Cohort Rank set at #1,174/1,730.

Heating COP
4.3 COP
Cohort Rank
#1,174/1,730
Verified Combos
1 SKU
Sample PD ID
3706876
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Keeprite HBR24V/H**C******1 Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Keeprite HBR24V/H**C******1 sits at 4.3 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.3 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329This series
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Keeprite HBR24V/H**C******1 residential equipment inspection. ThermalSpec Editorial Photography

How does Keeprite HBR24V/H**C******1 rank across federal compliance and ENERGY STAR cohorts?

Keeprite HBR24V/H**C******1 ranks #1,174 of 1,730 (tied with 193 others at 4.30 COP, more efficient than 21% of certified series) for Max COP (-0.20 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.3 COP and 25.0 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Keeprite in ThermalSpec's current SaferProducts feed.

Keeprite HBR24V/H**C******1 Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #1,174 of 1,730 (194 tied, beats 21% of peers) -0.20 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 25.0 EER +0.40 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.3 / Max EER 25.0 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does Keeprite HBR24V/H**C******1 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Keeprite HBR24V/H**C******1 estimates reflect 1 certified SKU combination tested under PD ID 3706876.

Heat_kWh = 50,000 kBTU / (4.3 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (25.0 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,408 kWh/yr$557/yr
Ground-Source Cooling Electricity (1,000 hrs)1,440 kWh/yr$235/yr
Total Annual Geothermal Operating Cost$792/yrState range: $617 to $2,287
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Keeprite HBR24V/H**C******1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Keeprite HBR24V/H**C******1 (PD ID 3706876).

HBR24V/H**C******1 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Keeprite HBR24V/H**C******1, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Keeprite HBR24V/H**C******1: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Keeprite HBR24V/H**C******1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Keeprite HBR24V/H**C******1 fitSingle-family replacement needing documented ENERGY STAR PD ID 3706876 with matching indoor air handler.
Skip Keeprite HBR24V/H**C******1 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Keeprite HBR24V/H**C******1 against GeoComfort GZT036******B and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

GeoComfort GZT036******B

4.3 COP · 24.9 EER · 1 combos

GeoSmart Energy GS018**1*0*J

4.3 COP · 24.7 EER · 1 combos

GeoSmart Energy GS042**1*(0,3)*K

4.3 COP · 23.3 EER · 1 combos

GeoSmart Energy GSZ060*1

4.3 COP · 23.6 EER · 2 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Keeprite HBR24V/H**C******1 compare with peer Geothermal Heat Pump units?

Keeprite HBR24V/H**C******1 holds #1,174 of 1,730 (194 tied, beats 21% of peers) out of 1,730 verified geothermal heat pump models (-0.20 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.3 COP. Closest same-cohort alternatives include GeoComfort GZT036******B.

DOE Regions

Where is Keeprite HBR24V/H**C******1 compliant for 2026 US installation?

Keeprite HBR24V/H**C******1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Keeprite HBR24V/H**C******1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Keeprite HBR24V/H**C******1 runs 3,408 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Keeprite HBR24V/H**C******1 cover?

Keeprite HBR24V/H**C******1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Keeprite HBR24V/H**C******1 handle extreme weather or cold snaps?

Keeprite HBR24V/H**C******1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Keeprite HBR24V/H**C******1?

Keeprite HBR24V/H**C******1 specifies Other compliance (PD ID 3706876); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Keeprite HBR24V/H**C******1 reach 4.3 COP?

Peak 4.3 COP represents the top tested AHRI pairing for Keeprite HBR24V/H**C******1 (PD ID 3706876); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Keeprite HBR24V/H**C******1?

Keeprite HBR24V/H**C******1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GeoComfort GZT036******B.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros