Hydron Module HCT072D — Geothermal Heat Pump Specifications
Hydron Module HCT072D (Geothermal Heat Pump, PD ID 2366889) holds 1 ENERGY STAR certified SKU rated at 4.2 COP — #1,368 of 1,730 (135 tied, beats 13.2% of peers), -0.30 COP. ENERGY STAR certified residential HVAC model. Hydron Module HCT072D — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.2 COP and Cohort Rank set at #1,368/1,730.
- Heating COP
- 4.2 COP
- Cohort Rank
- #1,368/1,730
- Verified Combos
- 1 SKU
- Sample PD ID
- 2366889
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | This series |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does Hydron Module HCT072D rank across federal compliance and ENERGY STAR cohorts?
Hydron Module HCT072D ranks #1,368 of 1,730 (tied with 134 others at 4.20 COP, more efficient than 13.2% of certified series) for Max COP (-0.30 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.2 COP and 21.7 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Hydron Module in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #1,368 of 1,730 (135 tied, beats 13.2% of peers) | -0.30 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 21.7 EER | -2.90 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.2 / Max EER 21.7 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does Hydron Module HCT072D require?
Modeled utility figures for Hydron Module HCT072D (Hydron Module) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,489 kWh/yr | $570/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,659 kWh/yr | $271/yr |
| Total Annual Geothermal Operating Cost | $841/yr | State range: $655 to $2,429 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Hydron Module HCT072D?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Hydron Module HCT072D (PD ID 2366889).
| HCT072D | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Hydron Module HCT072D, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Hydron Module HCT072D: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Hydron Module HCT072D exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Hydron Module HCT072D fit | Single-family replacement needing documented ENERGY STAR PD ID 2366889 with matching indoor air handler. |
| Skip Hydron Module HCT072D if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare Hydron Module HCT072D against Comfortmaker HS060*******1**1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Hydron Module HCT072D compare with peer Geothermal Heat Pump units?
Hydron Module HCT072D holds #1,368 of 1,730 (135 tied, beats 13.2% of peers) out of 1,730 verified geothermal heat pump models (-0.30 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.2 COP. Closest same-cohort alternatives include Comfortmaker HS060*******1**1.
Where is Hydron Module HCT072D compliant for 2026 US installation?
Hydron Module HCT072D: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Hydron Module HCT072D model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Hydron Module HCT072D runs 3,489 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Hydron Module HCT072D cover?
Hydron Module HCT072D covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Hydron Module HCT072D handle extreme weather or cold snaps?
Hydron Module HCT072D is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Hydron Module HCT072D?
Hydron Module HCT072D specifies R-410A compliance (PD ID 2366889); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Hydron Module HCT072D reach 4.2 COP?
Peak 4.2 COP represents the top tested AHRI pairing for Hydron Module HCT072D (PD ID 2366889); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Hydron Module HCT072D?
Hydron Module HCT072D requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Comfortmaker HS060*******1**1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.