Skip to main content
Geothermal Heat Pump · GeoSmart Energy · 1 ENERGY STAR Combinations

GeoSmart Energy NETZERO12KW2BWRB — Geothermal Heat Pump Specifications

GeoSmart Energy NETZERO12KW2BWRB (Geothermal Heat Pump, PD ID 2631855) holds 1 ENERGY STAR certified SKU rated at 4.0 COP — #1,623 of 1,730 (87 tied, beats 1.2% of peers), -0.50 COP. ENERGY STAR certified residential HVAC model. GeoSmart Energy NETZERO12KW2BWRB — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.0 COP and Cohort Rank set at #1,623/1,730.

Heating COP
4.0 COP
Cohort Rank
#1,623/1,730
Verified Combos
1 SKU
Sample PD ID
2631855
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
GeoSmart Energy NETZERO12KW2BWRB Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. GeoSmart Energy NETZERO12KW2BWRB sits at 4.0 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.0 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228This series
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
GeoSmart Energy NETZERO12KW2BWRB residential equipment inspection. ThermalSpec Editorial Photography

How does GeoSmart Energy NETZERO12KW2BWRB rank across federal compliance and ENERGY STAR cohorts?

GeoSmart Energy NETZERO12KW2BWRB ranks #1,623 of 1,730 (tied with 86 others at 4.00 COP, more efficient than 1.2% of certified series) for Max COP (-0.50 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Water unit delivering 4.0 COP and 20.3 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match GeoSmart Energy in ThermalSpec's current SaferProducts feed.

GeoSmart Energy NETZERO12KW2BWRB Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #1,623 of 1,730 (87 tied, beats 1.2% of peers) -0.50 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 20.3 EER -4.30 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.0 / Max EER 20.3 (Open Loop Water-to-Water)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does GeoSmart Energy NETZERO12KW2BWRB require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GeoSmart Energy NETZERO12KW2BWRB estimates reflect 1 certified SKU combination tested under PD ID 2631855.

Heat_kWh = 50,000 kBTU / (4.0 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (20.3 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,664 kWh/yr$598/yr
Ground-Source Cooling Electricity (1,000 hrs)1,773 kWh/yr$290/yr
Total Annual Geothermal Operating Cost$888/yrState range: $692 to $2,565
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to GeoSmart Energy NETZERO12KW2BWRB?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GeoSmart Energy NETZERO12KW2BWRB (PD ID 2631855).

NETZERO12KW2BWRB Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on GeoSmart Energy NETZERO12KW2BWRB, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across GeoSmart Energy NETZERO12KW2BWRB: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for GeoSmart Energy NETZERO12KW2BWRB exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal GeoSmart Energy NETZERO12KW2BWRB fitSingle-family replacement needing documented ENERGY STAR PD ID 2631855 with matching indoor air handler.
Skip GeoSmart Energy NETZERO12KW2BWRB ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare GeoSmart Energy NETZERO12KW2BWRB against Dual Air CFX060 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Dual Air CFX060

4.0 COP · 20.0 EER · 1 combos

Ecoforest 21610/U

4.0 COP · Open Loop Water-to-Water · 1 combos

Ecoforest 21612/U

4.0 COP · Open Loop Water-to-Water · 1 combos

Ecoforest 21620/U

4.0 COP · Open Loop Water-to-Water · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does GeoSmart Energy NETZERO12KW2BWRB compare with peer Geothermal Heat Pump units?

GeoSmart Energy NETZERO12KW2BWRB holds #1,623 of 1,730 (87 tied, beats 1.2% of peers) out of 1,730 verified geothermal heat pump models (-0.50 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.0 COP. Closest same-cohort alternatives include Dual Air CFX060.

DOE Regions

Where is GeoSmart Energy NETZERO12KW2BWRB compliant for 2026 US installation?

GeoSmart Energy NETZERO12KW2BWRB: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does GeoSmart Energy NETZERO12KW2BWRB model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, GeoSmart Energy NETZERO12KW2BWRB runs 3,664 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does GeoSmart Energy NETZERO12KW2BWRB cover?

GeoSmart Energy NETZERO12KW2BWRB covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does GeoSmart Energy NETZERO12KW2BWRB handle extreme weather or cold snaps?

GeoSmart Energy NETZERO12KW2BWRB is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern GeoSmart Energy NETZERO12KW2BWRB?

GeoSmart Energy NETZERO12KW2BWRB specifies R-410A compliance (PD ID 2631855); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in GeoSmart Energy NETZERO12KW2BWRB reach 4.0 COP?

Peak 4.0 COP represents the top tested AHRI pairing for GeoSmart Energy NETZERO12KW2BWRB (PD ID 2631855); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to GeoSmart Energy NETZERO12KW2BWRB?

GeoSmart Energy NETZERO12KW2BWRB requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Dual Air CFX060.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros