Skip to main content
Geothermal Heat Pump · GeoSmart Energy · 2 ENERGY STAR Combinations

GeoSmart Energy GTZ049*1*J — Geothermal Heat Pump Specifications

GeoSmart Energy GTZ049*1*J (Geothermal Heat Pump, PD ID 3845887) holds 2 ENERGY STAR certified SKUs rated at 4.8 COP — #383 of 1,730 (Top 27.2%, 88 tied), +0.30 COP. ENERGY STAR certified residential HVAC model. GeoSmart Energy GTZ049*1*J — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.8 COP and Cohort Rank set at #383/1,730.

Heating COP
4.8 COP
Cohort Rank
#383/1,730
Verified Combos
2 SKUs
Sample PD ID
3845887
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
GeoSmart Energy GTZ049*1*J Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. GeoSmart Energy GTZ049*1*J sits at 4.8 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.8 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244This series
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
GeoSmart Energy GTZ049*1*J residential equipment inspection. ThermalSpec Editorial Photography

How does GeoSmart Energy GTZ049*1*J rank across federal compliance and ENERGY STAR cohorts?

GeoSmart Energy GTZ049*1*J ranks #383 of 1,730 (tied with 87 others at 4.80 COP, top 27.2%, more efficient than 72.8% of certified series) for Max COP (+0.30 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.8 COP and 27.6 EER across closed- or open-loop residential piping.

GeoSmart Energy GTZ049*1*J Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #383 of 1,730 (Top 27.2%, 88 tied) +0.30 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 27.6 EER +3.00 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.8 / Max EER 27.6 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does GeoSmart Energy GTZ049*1*J require?

Modeled utility figures for GeoSmart Energy GTZ049*1*J (GeoSmart Energy) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.8 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (27.6 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,053 kWh/yr$499/yr
Ground-Source Cooling Electricity (1,000 hrs)1,304 kWh/yr$213/yr
Total Annual Geothermal Operating Cost$711/yrState range: $554 to $2,056
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to GeoSmart Energy GTZ049*1*J?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for GeoSmart Energy GTZ049*1*J (PD ID 3845887).

GTZ049*1*J Matched AHRI Coil —
GTZ049*1*J Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on GeoSmart Energy GTZ049*1*J, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across GeoSmart Energy GTZ049*1*J: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for GeoSmart Energy GTZ049*1*J exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal GeoSmart Energy GTZ049*1*J fitSingle-family replacement needing documented ENERGY STAR PD ID 3845887 with matching indoor air handler.
Skip GeoSmart Energy GTZ049*1*J ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare GeoSmart Energy GTZ049*1*J against ASTON 103H022**1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

ASTON 103H022**1

4.8 COP · 26.5 EER · 1 combos

ASTON 103H026**1

4.8 COP · 26.0 EER · 2 combos

ASTON 103H030**1

4.8 COP · 25.6 EER · 2 combos

Bosch RP036-1CSC-*****A

4.8 COP · 25.8 EER · 6 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does GeoSmart Energy GTZ049*1*J compare with peer Geothermal Heat Pump units?

GeoSmart Energy GTZ049*1*J holds #383 of 1,730 (Top 27.2%, 88 tied) out of 1,730 verified geothermal heat pump models (+0.30 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 4.8 COP. Closest same-cohort alternatives include ASTON 103H022**1.

DOE Regions

Where is GeoSmart Energy GTZ049*1*J compliant for 2026 US installation?

GeoSmart Energy GTZ049*1*J: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does GeoSmart Energy GTZ049*1*J model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, GeoSmart Energy GTZ049*1*J runs 3,053 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does GeoSmart Energy GTZ049*1*J cover?

GeoSmart Energy GTZ049*1*J covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does GeoSmart Energy GTZ049*1*J handle extreme weather or cold snaps?

GeoSmart Energy GTZ049*1*J is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern GeoSmart Energy GTZ049*1*J?

GeoSmart Energy GTZ049*1*J specifies R-410A compliance (PD ID 3845887); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in GeoSmart Energy GTZ049*1*J reach 4.8 COP?

Peak 4.8 COP represents the top tested AHRI pairing for GeoSmart Energy GTZ049*1*J (PD ID 3845887); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to GeoSmart Energy GTZ049*1*J?

GeoSmart Energy GTZ049*1*J requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ASTON 103H022**1.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.