GeoComfort GZT042 — Geothermal Heat Pump Specifications
GeoComfort GZT042 (Geothermal Heat Pump, PD ID 2368582) holds 1 ENERGY STAR certified SKU rated at 4.4 COP — #923 of 1,730 (251 tied, beats 32.2% of peers), -0.10 COP. ENERGY STAR certified residential HVAC model. GeoComfort GZT042 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.4 COP and Cohort Rank set at #923/1,730.
- Heating COP
- 4.4 COP
- Cohort Rank
- #923/1,730
- Verified Combos
- 1 SKU
- Sample PD ID
- 2368582
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | This series |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does GeoComfort GZT042 rank across federal compliance and ENERGY STAR cohorts?
GeoComfort GZT042 ranks #923 of 1,730 (tied with 250 others at 4.40 COP, more efficient than 32.2% of certified series) for Max COP (-0.10 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.4 COP and 27.0 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match GeoComfort in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #923 of 1,730 (251 tied, beats 32.2% of peers) | -0.10 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 27.0 EER | +2.40 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.4 / Max EER 27.0 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does GeoComfort GZT042 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GeoComfort GZT042 estimates reflect 1 certified SKU combination tested under PD ID 2368582.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,330 kWh/yr | $544/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,333 kWh/yr | $218/yr |
| Total Annual Geothermal Operating Cost | $761/yr | State range: $593 to $2,200 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GeoComfort GZT042?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GeoComfort GZT042 (PD ID 2368582).
| GZT042 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GeoComfort GZT042, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GeoComfort GZT042: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GeoComfort GZT042 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GeoComfort GZT042 fit | Single-family replacement needing documented ENERGY STAR PD ID 2368582 with matching indoor air handler. |
| Skip GeoComfort GZT042 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare GeoComfort GZT042 against Comfortmaker HBR42V/H**C******1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GeoComfort GZT042 compare with peer Geothermal Heat Pump units?
GeoComfort GZT042 holds #923 of 1,730 (251 tied, beats 32.2% of peers) out of 1,730 verified geothermal heat pump models (-0.10 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.4 COP. Closest same-cohort alternatives include Comfortmaker HBR42V/H**C******1.
Where is GeoComfort GZT042 compliant for 2026 US installation?
GeoComfort GZT042: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GeoComfort GZT042 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GeoComfort GZT042 runs 3,330 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GeoComfort GZT042 cover?
GeoComfort GZT042 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GeoComfort GZT042 handle extreme weather or cold snaps?
GeoComfort GZT042 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GeoComfort GZT042?
GeoComfort GZT042 specifies R-410A compliance (PD ID 2368582); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GeoComfort GZT042 reach 4.4 COP?
Peak 4.4 COP represents the top tested AHRI pairing for GeoComfort GZT042 (PD ID 2368582); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GeoComfort GZT042?
GeoComfort GZT042 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Comfortmaker HBR42V/H**C******1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.