GeoComfort GZS036*****1B — Geothermal Heat Pump Specifications
GeoComfort GZS036*****1B (Geothermal Heat Pump, PD ID 2635230) holds 1 ENERGY STAR certified SKU rated at 4.0 COP — #1,623 of 1,730 (87 tied, beats 1.2% of peers), -0.50 COP. ENERGY STAR certified residential HVAC model. GeoComfort GZS036*****1B — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.0 COP and Cohort Rank set at #1,623/1,730.
- Heating COP
- 4.0 COP
- Cohort Rank
- #1,623/1,730
- Verified Combos
- 1 SKU
- Sample PD ID
- 2635230
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | This series |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does GeoComfort GZS036*****1B rank across federal compliance and ENERGY STAR cohorts?
GeoComfort GZS036*****1B ranks #1,623 of 1,730 (tied with 86 others at 4.00 COP, more efficient than 1.2% of certified series) for Max COP (-0.50 COP vs 4.50 COP category median) across 1 certified SKU combination. Closed Loop Water-to-Air unit delivering 4.0 COP and 19.5 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match GeoComfort in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #1,623 of 1,730 (87 tied, beats 1.2% of peers) | -0.50 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 19.5 EER | -5.10 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.0 / Max EER 19.5 (Closed Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does GeoComfort GZS036*****1B require?
Modeled utility figures for GeoComfort GZS036*****1B (GeoComfort) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,664 kWh/yr | $598/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,846 kWh/yr | $301/yr |
| Total Annual Geothermal Operating Cost | $900/yr | State range: $701 to $2,600 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GeoComfort GZS036*****1B?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GeoComfort GZS036*****1B (PD ID 2635230).
| GZS036*****1B | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GeoComfort GZS036*****1B, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GeoComfort GZS036*****1B: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GeoComfort GZS036*****1B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GeoComfort GZS036*****1B fit | Single-family replacement needing documented ENERGY STAR PD ID 2635230 with matching indoor air handler. |
| Skip GeoComfort GZS036*****1B if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare GeoComfort GZS036*****1B against 5 SERIES NEW040*1* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GeoComfort GZS036*****1B compare with peer Geothermal Heat Pump units?
GeoComfort GZS036*****1B holds #1,623 of 1,730 (87 tied, beats 1.2% of peers) out of 1,730 verified geothermal heat pump models (-0.50 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.0 COP. Closest same-cohort alternatives include 5 SERIES NEW040*1*.
Where is GeoComfort GZS036*****1B compliant for 2026 US installation?
GeoComfort GZS036*****1B: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GeoComfort GZS036*****1B model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GeoComfort GZS036*****1B runs 3,664 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GeoComfort GZS036*****1B cover?
GeoComfort GZS036*****1B covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GeoComfort GZS036*****1B handle extreme weather or cold snaps?
GeoComfort GZS036*****1B is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GeoComfort GZS036*****1B?
GeoComfort GZS036*****1B specifies R-410A compliance (PD ID 2635230); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GeoComfort GZS036*****1B reach 4.0 COP?
Peak 4.0 COP represents the top tested AHRI pairing for GeoComfort GZS036*****1B (PD ID 2635230); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GeoComfort GZS036*****1B?
GeoComfort GZS036*****1B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 5 SERIES NEW040*1*.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages