GeoComfort GYT072* — Geothermal Heat Pump Specifications
GeoComfort GYT072* (Geothermal Heat Pump, PD ID 3998448) holds 2 ENERGY STAR certified SKUs rated at 4.7 COP — #471 of 1,730 (Top 36.2%, 156 tied), +0.20 COP. ENERGY STAR certified residential HVAC model. GeoComfort GYT072* — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.7 COP and Cohort Rank set at #471/1,730.
- Heating COP
- 4.7 COP
- Cohort Rank
- #471/1,730
- Verified Combos
- 2 SKUs
- Sample PD ID
- 3998448
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | This series |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does GeoComfort GYT072* rank across federal compliance and ENERGY STAR cohorts?
GeoComfort GYT072* ranks #471 of 1,730 (tied with 155 others at 4.70 COP, top 36.2%, more efficient than 63.8% of certified series) for Max COP (+0.20 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.7 COP and 24.9 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match GeoComfort in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #471 of 1,730 (Top 36.2%, 156 tied) | +0.20 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 24.9 EER | +0.30 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.7 / Max EER 24.9 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: Other |
How much annual energy and operating cost does GeoComfort GYT072* require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GeoComfort GYT072* estimates reflect 2 certified SKU combinations tested under PD ID 3998448.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,118 kWh/yr | $509/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,446 kWh/yr | $236/yr |
| Total Annual Geothermal Operating Cost | $745/yr | State range: $581 to $2,153 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GeoComfort GYT072*?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for GeoComfort GYT072* (PD ID 3998448).
| GYT072* | Matched AHRI Coil | — | |
| GYT072* | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GeoComfort GYT072*, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GeoComfort GYT072*: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for GeoComfort GYT072* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GeoComfort GYT072* fit | Single-family replacement needing documented ENERGY STAR PD ID 3998448 with matching indoor air handler. |
| Skip GeoComfort GYT072* if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare GeoComfort GYT072* against Carrier GB036H******1**1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GeoComfort GYT072* compare with peer Geothermal Heat Pump units?
GeoComfort GYT072* holds #471 of 1,730 (Top 36.2%, 156 tied) out of 1,730 verified geothermal heat pump models (+0.20 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 4.7 COP. Closest same-cohort alternatives include Carrier GB036H******1**1.
Where is GeoComfort GYT072* compliant for 2026 US installation?
GeoComfort GYT072*: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GeoComfort GYT072* model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GeoComfort GYT072* runs 3,118 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GeoComfort GYT072* cover?
GeoComfort GYT072* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GeoComfort GYT072* handle extreme weather or cold snaps?
GeoComfort GYT072* is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GeoComfort GYT072*?
GeoComfort GYT072* specifies Other compliance (PD ID 3998448); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in GeoComfort GYT072* reach 4.7 COP?
Peak 4.7 COP represents the top tested AHRI pairing for GeoComfort GYT072* (PD ID 3998448); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GeoComfort GYT072*?
GeoComfort GYT072* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Carrier GB036H******1**1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.