Skip to main content
Geothermal Heat Pump · Enertech · 1 ENERGY STAR Combinations

Enertech EVS009* — Geothermal Heat Pump Specifications

Enertech EVS009* (Geothermal Heat Pump, PD ID 3998477) holds 1 ENERGY STAR certified SKU rated at 4.4 COP — #923 of 1,730 (251 tied, beats 32.2% of peers), -0.10 COP. ENERGY STAR certified residential HVAC model. Enertech EVS009* — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.4 COP and Cohort Rank set at #923/1,730.

Heating COP
4.4 COP
Cohort Rank
#923/1,730
Verified Combos
1 SKU
Sample PD ID
3998477
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Enertech EVS009* Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Enertech EVS009* sits at 4.4 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.4 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251This series
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Enertech EVS009* residential equipment inspection. ThermalSpec Editorial Photography

How does Enertech EVS009* rank across federal compliance and ENERGY STAR cohorts?

Enertech EVS009* ranks #923 of 1,730 (tied with 250 others at 4.40 COP, more efficient than 32.2% of certified series) for Max COP (-0.10 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.4 COP and 24.2 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Enertech in ThermalSpec's current SaferProducts feed.

Enertech EVS009* Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #923 of 1,730 (251 tied, beats 32.2% of peers) -0.10 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 24.2 EER -0.40 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.4 / Max EER 24.2 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does Enertech EVS009* require?

Modeled utility figures for Enertech EVS009* (Enertech) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.4 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (24.2 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,330 kWh/yr$544/yr
Ground-Source Cooling Electricity (1,000 hrs)1,488 kWh/yr$243/yr
Total Annual Geothermal Operating Cost$787/yrState range: $613 to $2,273
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Enertech EVS009*?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Enertech EVS009* (PD ID 3998477).

EVS009* Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Enertech EVS009*, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Enertech EVS009*: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Enertech EVS009* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Enertech EVS009* fitSingle-family replacement needing documented ENERGY STAR PD ID 3998477 with matching indoor air handler.
Skip Enertech EVS009* ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Enertech EVS009* against Climatemaster TES/P049B and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Climatemaster TES/P049B

4.4 COP · 26.2 EER · 2 combos

Climatemaster VEV/H/D0930

4.4 COP · 33.8 EER · 1 combos

Comfort-Aire HZS048B

4.4 COP · 26.2 EER · 3 combos

Comfort-Aire MJN060A

4.4 COP · 25.8 EER · 2 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Enertech EVS009* compare with peer Geothermal Heat Pump units?

Enertech EVS009* holds #923 of 1,730 (251 tied, beats 32.2% of peers) out of 1,730 verified geothermal heat pump models (-0.10 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.4 COP. Closest same-cohort alternatives include Climatemaster TES/P049B.

DOE Regions

Where is Enertech EVS009* compliant for 2026 US installation?

Enertech EVS009*: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Enertech EVS009* model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Enertech EVS009* runs 3,330 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Enertech EVS009* cover?

Enertech EVS009* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Enertech EVS009* handle extreme weather or cold snaps?

Enertech EVS009* is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Enertech EVS009*?

Enertech EVS009* specifies Other compliance (PD ID 3998477); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Enertech EVS009* reach 4.4 COP?

Peak 4.4 COP represents the top tested AHRI pairing for Enertech EVS009* (PD ID 3998477); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Enertech EVS009*?

Enertech EVS009* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Climatemaster TES/P049B.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros