Skip to main content
Geothermal Heat Pump · Comfortmaker · 1 ENERGY STAR Combinations

Comfortmaker HB036V******1**1 — Geothermal Heat Pump Specifications

Comfortmaker HB036V******1**1 (Geothermal Heat Pump, PD ID 3845772) holds 1 ENERGY STAR certified SKU rated at 4.9 COP — #281 of 1,730 (Top 22.1%, 102 tied), +0.40 COP. ENERGY STAR certified residential HVAC model. Comfortmaker HB036V******1**1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.9 COP and Cohort Rank set at #281/1,730.

Heating COP
4.9 COP
Cohort Rank
#281/1,730
Verified Combos
1 SKU
Sample PD ID
3845772
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Comfortmaker HB036V******1**1 Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Comfortmaker HB036V******1**1 sits at 4.9 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.9 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310This series
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Comfortmaker HB036V******1**1 residential equipment inspection. ThermalSpec Editorial Photography

How does Comfortmaker HB036V******1**1 rank across federal compliance and ENERGY STAR cohorts?

Comfortmaker HB036V******1**1 ranks #281 of 1,730 (tied with 101 others at 4.90 COP, top 22.1%, more efficient than 77.9% of certified series) for Max COP (+0.40 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.9 COP and 25.9 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Comfortmaker in ThermalSpec's current SaferProducts feed.

Comfortmaker HB036V******1**1 Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #281 of 1,730 (Top 22.1%, 102 tied) +0.40 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 25.9 EER +1.30 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.9 / Max EER 25.9 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does Comfortmaker HB036V******1**1 require?

Modeled utility figures for Comfortmaker HB036V******1**1 (Comfortmaker) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.9 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (25.9 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity2,991 kWh/yr$488/yr
Ground-Source Cooling Electricity (1,000 hrs)1,390 kWh/yr$227/yr
Total Annual Geothermal Operating Cost$715/yrState range: $557 to $2,067
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Comfortmaker HB036V******1**1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Comfortmaker HB036V******1**1 (PD ID 3845772).

HB036V******1**1 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Comfortmaker HB036V******1**1, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Comfortmaker HB036V******1**1: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Comfortmaker HB036V******1**1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Comfortmaker HB036V******1**1 fitSingle-family replacement needing documented ENERGY STAR PD ID 3845772 with matching indoor air handler.
Skip Comfortmaker HB036V******1**1 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Comfortmaker HB036V******1**1 against Arcoaire HCR24H**N******1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Arcoaire HCR24H**N******1

4.9 COP · 27.8 EER · 2 combos

Arcoaire HCR24V**C******1

4.9 COP · 27.8 EER · 2 combos

Arcoaire HCR24V**N******1

4.9 COP · 27.8 EER · 2 combos

Arcoaire HS024SR*N******1

4.9 COP · 26.8 EER · 3 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Comfortmaker HB036V******1**1 compare with peer Geothermal Heat Pump units?

Comfortmaker HB036V******1**1 holds #281 of 1,730 (Top 22.1%, 102 tied) out of 1,730 verified geothermal heat pump models (+0.40 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.9 COP. Closest same-cohort alternatives include Arcoaire HCR24H**N******1.

DOE Regions

Where is Comfortmaker HB036V******1**1 compliant for 2026 US installation?

Comfortmaker HB036V******1**1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Comfortmaker HB036V******1**1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Comfortmaker HB036V******1**1 runs 2,991 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Comfortmaker HB036V******1**1 cover?

Comfortmaker HB036V******1**1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Comfortmaker HB036V******1**1 handle extreme weather or cold snaps?

Comfortmaker HB036V******1**1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Comfortmaker HB036V******1**1?

Comfortmaker HB036V******1**1 specifies R-410A compliance (PD ID 3845772); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Comfortmaker HB036V******1**1 reach 4.9 COP?

Peak 4.9 COP represents the top tested AHRI pairing for Comfortmaker HB036V******1**1 (PD ID 3845772); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Comfortmaker HB036V******1**1?

Comfortmaker HB036V******1**1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Arcoaire HCR24H**N******1.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros