Comfort-Aire MJN048A — Geothermal Heat Pump Specifications

Comfort-Aire MJN048A (Geothermal Heat Pump, PD ID 4512442) holds 2 ENERGY STAR certified SKUs rated at 4.5 COP — #790 of 1,730 (133 tied at median), Equal to 4.50 COP category median. ENERGY STAR certified residential HVAC model. Comfort-Aire MJN048A — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.5 COP and Cohort Rank set at #790/1,730.

Heating COP
4.5 COP
Cohort Rank
#790/1,730
Verified Combos
2 SKUs
Sample PD ID
4512442
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Comfort-Aire MJN048A Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Comfort-Aire MJN048A sits at 4.5 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.5 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296This series
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Comfort-Aire MJN048A residential equipment inspection. ThermalSpec Editorial Photography

How does Comfort-Aire MJN048A rank across federal compliance and ENERGY STAR cohorts?

Comfort-Aire MJN048A ranks #790 of 1,730 (tied with 132 others at 4.50 COP, more efficient than 46.7% of certified series) for Max COP (Equal to 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.5 COP and 26.8 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Comfort-Aire in ThermalSpec's current SaferProducts feed.

Comfort-Aire MJN048A Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #790 of 1,730 (133 tied at median) Equal to 4.50 COP category median
Closed/Open Loop EER vs Cohort 26.8 EER +2.20 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.5 / Max EER 26.8 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does Comfort-Aire MJN048A require?

Annual cost outputs combine Comfort-Aire MJN048A's 4.5 COP rating and EIA national tariffs across single-family runtime hours.

Heat_kWh = 50,000 kBTU / (4.5 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (26.8 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,256 kWh/yr$532/yr
Ground-Source Cooling Electricity (1,000 hrs)1,343 kWh/yr$219/yr
Total Annual Geothermal Operating Cost$751/yrState range: $585 to $2,170
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Comfort-Aire MJN048A?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Comfort-Aire MJN048A (PD ID 4512442).

MJN048A Matched AHRI Coil —
MJN048A Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Comfort-Aire MJN048A, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Comfort-Aire MJN048A: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for Comfort-Aire MJN048A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Comfort-Aire MJN048A fitSingle-family replacement needing documented ENERGY STAR PD ID 4512442 with matching indoor air handler.
Skip Comfort-Aire MJN048A ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Comfort-Aire MJN048A against 5 SERIES INDOOR SPLITS NDZ064J1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

5 SERIES INDOOR SPLITS NDZ064J1

4.5 COP · 25.8 EER · 2 combos

AE Air HRCX09*-6

4.5 COP · 26.5 EER · 1 combos

Arcoaire HB024H/V******1**1

4.5 COP · 27.4 EER · 1 combos

Arcoaire HB048H******1**1

4.5 COP · 24.0 EER · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Comfort-Aire MJN048A compare with peer Geothermal Heat Pump units?

Comfort-Aire MJN048A holds #790 of 1,730 (133 tied at median) out of 1,730 verified geothermal heat pump models (Equal to 4.50 COP category median), spanning 2 certified SKUs up to 4.5 COP. Closest same-cohort alternatives include 5 SERIES INDOOR SPLITS NDZ064J1.

DOE Regions

Where is Comfort-Aire MJN048A compliant for 2026 US installation?

Comfort-Aire MJN048A: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Comfort-Aire MJN048A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Comfort-Aire MJN048A runs 3,256 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Comfort-Aire MJN048A cover?

Comfort-Aire MJN048A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Comfort-Aire MJN048A handle extreme weather or cold snaps?

Comfort-Aire MJN048A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Comfort-Aire MJN048A?

Comfort-Aire MJN048A specifies Other compliance (PD ID 4512442); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in Comfort-Aire MJN048A reach 4.5 COP?

Peak 4.5 COP represents the top tested AHRI pairing for Comfort-Aire MJN048A (PD ID 4512442); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Comfort-Aire MJN048A?

Comfort-Aire MJN048A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 5 SERIES INDOOR SPLITS NDZ064J1.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)