Skip to main content
Geothermal Heat Pump · Bosch · 1 ENERGY STAR Combinations

Bosch RF048-1VT/HZN-*****A — Geothermal Heat Pump Specifications

Bosch RF048-1VT/HZN-*****A (Geothermal Heat Pump, PD ID 3706821) holds 1 ENERGY STAR certified SKU rated at 4.4 COP — #923 of 1,730 (251 tied, beats 32.2% of peers), -0.10 COP. ENERGY STAR certified residential HVAC model. Bosch RF048-1VT/HZN-*****A — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.4 COP and Cohort Rank set at #923/1,730.

Heating COP
4.4 COP
Cohort Rank
#923/1,730
Verified Combos
1 SKU
Sample PD ID
3706821
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Bosch RF048-1VT/HZN-*****A Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Bosch RF048-1VT/HZN-*****A sits at 4.4 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.4 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251This series
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Bosch RF048-1VT/HZN-*****A residential equipment inspection. ThermalSpec Editorial Photography

How does Bosch RF048-1VT/HZN-*****A rank across federal compliance and ENERGY STAR cohorts?

Bosch RF048-1VT/HZN-*****A ranks #923 of 1,730 (tied with 250 others at 4.40 COP, more efficient than 32.2% of certified series) for Max COP (-0.10 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.4 COP and 24.0 EER across closed- or open-loop residential piping.

Bosch RF048-1VT/HZN-*****A Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #923 of 1,730 (251 tied, beats 32.2% of peers) -0.10 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 24.0 EER -0.60 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.4 / Max EER 24.0 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: Other

How much annual energy and operating cost does Bosch RF048-1VT/HZN-*****A require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Bosch RF048-1VT/HZN-*****A estimates reflect 1 certified SKU combination tested under PD ID 3706821.

Heat_kWh = 50,000 kBTU / (4.4 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (24.0 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,330 kWh/yr$544/yr
Ground-Source Cooling Electricity (1,000 hrs)1,500 kWh/yr$245/yr
Total Annual Geothermal Operating Cost$789/yrState range: $614 to $2,279
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Bosch RF048-1VT/HZN-*****A?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Bosch RF048-1VT/HZN-*****A (PD ID 3706821).

RF048-1VT/HZN-*****A Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Bosch RF048-1VT/HZN-*****A, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Bosch RF048-1VT/HZN-*****A: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Bosch RF048-1VT/HZN-*****A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Bosch RF048-1VT/HZN-*****A fitSingle-family replacement needing documented ENERGY STAR PD ID 3706821 with matching indoor air handler.
Skip Bosch RF048-1VT/HZN-*****A ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Bosch RF048-1VT/HZN-*****A against AE Air HRCX24*-6 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

AE Air HRCX24*-6

4.4 COP · 26.5 EER · 1 combos

Arcoaire HB018H******1**2

4.4 COP · 24.7 EER · 1 combos

Arcoaire HB018V******1**2

4.4 COP · 25.3 EER · 1 combos

Arcoaire HBR18V/H**C******1

4.4 COP · 24.0 EER · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Bosch RF048-1VT/HZN-*****A compare with peer Geothermal Heat Pump units?

Bosch RF048-1VT/HZN-*****A holds #923 of 1,730 (251 tied, beats 32.2% of peers) out of 1,730 verified geothermal heat pump models (-0.10 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.4 COP. Closest same-cohort alternatives include AE Air HRCX24*-6.

DOE Regions

Where is Bosch RF048-1VT/HZN-*****A compliant for 2026 US installation?

Bosch RF048-1VT/HZN-*****A: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Bosch RF048-1VT/HZN-*****A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Bosch RF048-1VT/HZN-*****A runs 3,330 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Bosch RF048-1VT/HZN-*****A cover?

Bosch RF048-1VT/HZN-*****A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Bosch RF048-1VT/HZN-*****A handle extreme weather or cold snaps?

Bosch RF048-1VT/HZN-*****A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Bosch RF048-1VT/HZN-*****A?

Bosch RF048-1VT/HZN-*****A specifies Other compliance (PD ID 3706821); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Bosch RF048-1VT/HZN-*****A reach 4.4 COP?

Peak 4.4 COP represents the top tested AHRI pairing for Bosch RF048-1VT/HZN-*****A (PD ID 3706821); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Bosch RF048-1VT/HZN-*****A?

Bosch RF048-1VT/HZN-*****A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AE Air HRCX24*-6.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros