YORK BY JOHNSON CONTROLS YP9C080C16MP13 — Residential Furnace Specifications
YORK BY JOHNSON CONTROLS YP9C080C16MP13 (Residential Furnace, PD ID 4726491) holds 1 ENERGY STAR certified SKU rated at 97.7% AFUE — #70 of 3,740 (Top 2.8%, 36 tied), +1.70% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. YORK BY JOHNSON CONTROLS YP9C080C16MP13 — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.7% AFUE and Cohort Rank set at #70/3,740.
- Thermal Efficiency
- 97.7% AFUE
- Cohort Rank
- #70/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4726491
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | This series |
How does YORK BY JOHNSON CONTROLS YP9C080C16MP13 rank across federal compliance and ENERGY STAR cohorts?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 ranks #70 of 3,740 (tied with 35 others at 97.7% AFUE, top 2.8%, more efficient than 97.2% of certified series) for Max AFUE (+1.70% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.7% AFUE (+17.7 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-11-05.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #70 of 3,740 (Top 2.8%, 36 tied) | +1.70% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (97.7% AFUE, +17.7 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does YORK BY JOHNSON CONTROLS YP9C080C16MP13 require?
Annual cost outputs combine YORK BY JOHNSON CONTROLS YP9C080C16MP13's 97.7% AFUE rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 511.8 therms/yr | 5,988 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $742/yr | State range: $379 (ID) to $2,585 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 113.2 therms/yr | $164/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to YORK BY JOHNSON CONTROLS YP9C080C16MP13?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for YORK BY JOHNSON CONTROLS YP9C080C16MP13 (PD ID 4726491).
| YP9C080C16MP13 | Matched AHRI Coil | — | / 97.7% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on YORK BY JOHNSON CONTROLS YP9C080C16MP13, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across YORK BY JOHNSON CONTROLS YP9C080C16MP13: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for YORK BY JOHNSON CONTROLS YP9C080C16MP13 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- YORK BY JOHNSON CONTROLS YP9C080C16MP13 condensing combustion at 97.7% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal YORK BY JOHNSON CONTROLS YP9C080C16MP13 fit | Single-family replacement needing documented ENERGY STAR PD ID 4726491 with matching indoor air handler. |
| Skip YORK BY JOHNSON CONTROLS YP9C080C16MP13 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare YORK BY JOHNSON CONTROLS YP9C080C16MP13 against CHAMPION HEATING AND COOLING TP9C080C16MP13 and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does YORK BY JOHNSON CONTROLS YP9C080C16MP13 compare with peer Residential Furnace units?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 holds #70 of 3,740 (Top 2.8%, 36 tied) out of 3,740 verified residential furnace models (+1.70% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.7% AFUE. Closest same-cohort alternatives include CHAMPION HEATING AND COOLING TP9C080C16MP13.
Where is YORK BY JOHNSON CONTROLS YP9C080C16MP13 compliant for 2026 US installation?
YORK BY JOHNSON CONTROLS YP9C080C16MP13: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does YORK BY JOHNSON CONTROLS YP9C080C16MP13 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, YORK BY JOHNSON CONTROLS YP9C080C16MP13 runs 511.8 therms/yr across standard cooling/heating hours.
What capacity band and airflow does YORK BY JOHNSON CONTROLS YP9C080C16MP13 cover?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does YORK BY JOHNSON CONTROLS YP9C080C16MP13 handle extreme weather or cold snaps?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern YORK BY JOHNSON CONTROLS YP9C080C16MP13?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 specifies sealed combustion compliance (PD ID 4726491); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in YORK BY JOHNSON CONTROLS YP9C080C16MP13 reach 97.7% AFUE?
Peak 97.7% AFUE represents the top tested AHRI pairing for YORK BY JOHNSON CONTROLS YP9C080C16MP13 (PD ID 4726491); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to YORK BY JOHNSON CONTROLS YP9C080C16MP13?
YORK BY JOHNSON CONTROLS YP9C080C16MP13 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include CHAMPION HEATING AND COOLING TP9C080C16MP13.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages