Skip to main content
Residential Furnace · WEATHERMAKER · 1 ENERGY STAR Combinations

WEATHERMAKER PG96VTAB66120D — Residential Furnace Specifications

WEATHERMAKER PG96VTAB66120D (Residential Furnace, PD ID 4681370) holds 1 ENERGY STAR certified SKU rated at 96.7% AFUE — #980 of 3,740 (Top 29.7%, 131 tied), +0.70% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. WEATHERMAKER PG96VTAB66120D — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.7% AFUE and Cohort Rank set at #980/3,740.

Thermal Efficiency
96.7% AFUE
Cohort Rank
#980/3,740
Verified Combos
1 SKU
Sample PD ID
4681370
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
WEATHERMAKER PG96VTAB66120D Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. WEATHERMAKER PG96VTAB66120D sits at 96.7% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 96.7% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566Peer range
96.3 - 97.7% AFUE1027This series
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
WEATHERMAKER PG96VTAB66120D residential equipment inspection. ThermalSpec Editorial Photography

How does WEATHERMAKER PG96VTAB66120D rank across federal compliance and ENERGY STAR cohorts?

WEATHERMAKER PG96VTAB66120D ranks #980 of 3,740 (tied with 130 others at 96.7% AFUE, top 29.7%, more efficient than 70.3% of certified series) for Max AFUE (+0.70% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.7% AFUE (+16.7 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.

WEATHERMAKER PG96VTAB66120D Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #980 of 3,740 (Top 29.7%, 131 tied) +0.70% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (96.7% AFUE, +16.7 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does WEATHERMAKER PG96VTAB66120D require?

Annual cost outputs combine WEATHERMAKER PG96VTAB66120D's 96.7% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (96.7% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)517.1 therms/yr6,050 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$750/yrState range: $383 (ID) to $2,611 (HI)
Fuel Saved vs 80% AFUE Baseline107.9 therms/yr$156/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to WEATHERMAKER PG96VTAB66120D?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for WEATHERMAKER PG96VTAB66120D (PD ID 4681370).

PG96VTAB66120D Matched AHRI Coil — / 96.7% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on WEATHERMAKER PG96VTAB66120D, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across WEATHERMAKER PG96VTAB66120D: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for WEATHERMAKER PG96VTAB66120D exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • WEATHERMAKER PG96VTAB66120D condensing combustion at 96.7% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal WEATHERMAKER PG96VTAB66120D fitSingle-family replacement needing documented ENERGY STAR PD ID 4681370 with matching indoor air handler.
Skip WEATHERMAKER PG96VTAB66120D ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare WEATHERMAKER PG96VTAB66120D against Keeprite N96VSN0401712B and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Keeprite N96VSN0401712B

96.7% AFUE · Natural Gas, Propane Gas · 1 combos

Kenmore F96CTN0802120B

96.7% AFUE · Natural Gas, Propane Gas · 1 combos

Kenmore F96VTN0802120B

96.7% AFUE · Natural Gas, Propane Gas · 1 combos

Kenmore F96VTN1202422B

96.7% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does WEATHERMAKER PG96VTAB66120D compare with peer Residential Furnace units?

WEATHERMAKER PG96VTAB66120D holds #980 of 3,740 (Top 29.7%, 131 tied) out of 3,740 verified residential furnace models (+0.70% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 96.7% AFUE. Closest same-cohort alternatives include Keeprite N96VSN0401712B.

DOE Regions

Where is WEATHERMAKER PG96VTAB66120D compliant for 2026 US installation?

WEATHERMAKER PG96VTAB66120D: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does WEATHERMAKER PG96VTAB66120D model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, WEATHERMAKER PG96VTAB66120D runs 517.1 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does WEATHERMAKER PG96VTAB66120D cover?

WEATHERMAKER PG96VTAB66120D covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does WEATHERMAKER PG96VTAB66120D handle extreme weather or cold snaps?

WEATHERMAKER PG96VTAB66120D delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern WEATHERMAKER PG96VTAB66120D?

WEATHERMAKER PG96VTAB66120D specifies sealed combustion compliance (PD ID 4681370); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in WEATHERMAKER PG96VTAB66120D reach 96.7% AFUE?

Peak 96.7% AFUE represents the top tested AHRI pairing for WEATHERMAKER PG96VTAB66120D (PD ID 4681370); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to WEATHERMAKER PG96VTAB66120D?

WEATHERMAKER PG96VTAB66120D requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Keeprite N96VSN0401712B.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros