WEATHERMAKER PG96MSAA66120D — Residential Furnace Specifications
WEATHERMAKER PG96MSAA66120D (Residential Furnace, PD ID 4677352) holds 1 ENERGY STAR certified SKU rated at 96.1% AFUE — #1,338 of 3,740 (Top 39.9%, 155 tied), +0.10% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. WEATHERMAKER PG96MSAA66120D — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.1% AFUE and Cohort Rank set at #1,338/3,740.
- Thermal Efficiency
- 96.1% AFUE
- Cohort Rank
- #1,338/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4677352
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | This series |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does WEATHERMAKER PG96MSAA66120D rank across federal compliance and ENERGY STAR cohorts?
WEATHERMAKER PG96MSAA66120D ranks #1,338 of 3,740 (tied with 154 others at 96.1% AFUE, top 39.9%, more efficient than 60.1% of certified series) for Max AFUE (+0.10% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.1% AFUE (+16.1 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-07-28.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #1,338 of 3,740 (Top 39.9%, 155 tied) | +0.10% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (96.1% AFUE, +16.1 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does WEATHERMAKER PG96MSAA66120D require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, WEATHERMAKER PG96MSAA66120D estimates reflect 1 certified SKU combination tested under PD ID 4677352.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 520.3 therms/yr | 6,088 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $754/yr | State range: $385 (ID) to $2,628 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 104.7 therms/yr | $152/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to WEATHERMAKER PG96MSAA66120D?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for WEATHERMAKER PG96MSAA66120D (PD ID 4677352).
| PG96MSAA66120D | Matched AHRI Coil | — | / 96.1% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on WEATHERMAKER PG96MSAA66120D, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across WEATHERMAKER PG96MSAA66120D: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for WEATHERMAKER PG96MSAA66120D exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- WEATHERMAKER PG96MSAA66120D condensing combustion at 96.1% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal WEATHERMAKER PG96MSAA66120D fit | Single-family replacement needing documented ENERGY STAR PD ID 4677352 with matching indoor air handler. |
| Skip WEATHERMAKER PG96MSAA66120D if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare WEATHERMAKER PG96MSAA66120D against Heil G97CTN1002122A*H and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does WEATHERMAKER PG96MSAA66120D compare with peer Residential Furnace units?
WEATHERMAKER PG96MSAA66120D holds #1,338 of 3,740 (Top 39.9%, 155 tied) out of 3,740 verified residential furnace models (+0.10% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 96.1% AFUE. Closest same-cohort alternatives include Heil G97CTN1002122A*H.
Where is WEATHERMAKER PG96MSAA66120D compliant for 2026 US installation?
WEATHERMAKER PG96MSAA66120D: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does WEATHERMAKER PG96MSAA66120D model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, WEATHERMAKER PG96MSAA66120D runs 520.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does WEATHERMAKER PG96MSAA66120D cover?
WEATHERMAKER PG96MSAA66120D covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does WEATHERMAKER PG96MSAA66120D handle extreme weather or cold snaps?
WEATHERMAKER PG96MSAA66120D delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern WEATHERMAKER PG96MSAA66120D?
WEATHERMAKER PG96MSAA66120D specifies sealed combustion compliance (PD ID 4677352); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in WEATHERMAKER PG96MSAA66120D reach 96.1% AFUE?
Peak 96.1% AFUE represents the top tested AHRI pairing for WEATHERMAKER PG96MSAA66120D (PD ID 4677352); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to WEATHERMAKER PG96MSAA66120D?
WEATHERMAKER PG96MSAA66120D requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Heil G97CTN1002122A*H.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.