Sure S97MV0703A17DHS (Residential Furnace, PD ID 4692985) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Sure S97MV0703A17DHS — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

Thermal Efficiency
97.0% AFUE
Cohort Rank
#167/3,740
Verified Combos
1 SKU
Sample PD ID
4692985
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
Sure S97MV0703A17DHS Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. Sure S97MV0703A17DHS sits at 97.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 97.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566Peer range
96.3 - 97.7% AFUE1027This series
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Sure S97MV0703A17DHS residential equipment inspection. ThermalSpec Editorial Photography

How does Sure S97MV0703A17DHS rank across federal compliance and ENERGY STAR cohorts?

Sure S97MV0703A17DHS ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-24.

Sure S97MV0703A17DHS Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #167 of 3,740 (Top 26.2%, 813 tied) +1.00% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does Sure S97MV0703A17DHS require?

Modeled utility figures for Sure S97MV0703A17DHS (Sure) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max AFUE ratings.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)515.5 therms/yr6,031 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$747/yrState range: $381 (ID) to $2,603 (HI)
Fuel Saved vs 80% AFUE Baseline109.5 therms/yr$159/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Sure S97MV0703A17DHS?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Sure S97MV0703A17DHS (PD ID 4692985).

S97MV0703A17DHS Matched AHRI Coil — / 97.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Sure S97MV0703A17DHS, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Sure S97MV0703A17DHS: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Sure S97MV0703A17DHS exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Sure S97MV0703A17DHS condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Sure S97MV0703A17DHS fitSingle-family replacement needing documented ENERGY STAR PD ID 4692985 with matching indoor air handler.
Skip Sure S97MV0703A17DHS ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare Sure S97MV0703A17DHS against Rheem R972V0403A17UPS and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Rheem R972V0403A17UPS

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R972V0603A17UPS

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R972V0703A17UPS

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R972V0705A21UPS

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Sure S97MV0703A17DHS compare with peer Residential Furnace units?

Sure S97MV0703A17DHS holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Rheem R972V0403A17UPS.

DOE Regions

Where is Sure S97MV0703A17DHS compliant for 2026 US installation?

Sure S97MV0703A17DHS: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Sure S97MV0703A17DHS model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Sure S97MV0703A17DHS runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Sure S97MV0703A17DHS cover?

Sure S97MV0703A17DHS covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Sure S97MV0703A17DHS handle extreme weather or cold snaps?

Sure S97MV0703A17DHS delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Sure S97MV0703A17DHS?

Sure S97MV0703A17DHS specifies sealed combustion compliance (PD ID 4692985); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Sure S97MV0703A17DHS reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for Sure S97MV0703A17DHS (PD ID 4692985); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Sure S97MV0703A17DHS?

Sure S97MV0703A17DHS requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Rheem R972V0403A17UPS.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros