Spirit VHF-ABT — Residential Furnace Specifications
Spirit VHF-ABT (Residential Furnace, PD ID 4719610) holds 1 ENERGY STAR certified SKU rated at 87.0% AFUE — #3,699 of 3,740 (42 tied at floor), -9.00% AFUE. Meets 80%+ AFUE baseline under 10 CFR 430.32(e). Spirit VHF-ABT — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 87.0% AFUE and Cohort Rank set at #3,699/3,740.
- Thermal Efficiency
- 87.0% AFUE
- Cohort Rank
- #3,699/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4719610
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | This series |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does Spirit VHF-ABT rank across federal compliance and ENERGY STAR cohorts?
Spirit VHF-ABT ties with 41 peers at 87.0% AFUE (the cohort floor across 3,740 certified series) for Max AFUE (-9.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Non-condensing Oil model at 87.0% AFUE suited to Type B metal chimney venting with ENERGY STAR qualification dated 2026-10-26. Zero CPSC residential HVAC recall filings match Spirit in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #3,699 of 3,740 (42 tied at floor) | -9.00% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (87.0% AFUE, +7.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | NON-CONDENSING | 80%-89% AFUE uses Type B metal chimney venting |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does Spirit VHF-ABT require?
Annual cost outputs combine Spirit VHF-ABT's 87.0% AFUE rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 574.7 therms/yr | 6,724 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $833/yr | State range: $425 (ID) to $2,902 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 50.3 therms/yr | $73/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Spirit VHF-ABT?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Spirit VHF-ABT (PD ID 4719610).
| VHF-ABT | Matched AHRI Coil | — | / 87.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Spirit VHF-ABT, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Spirit VHF-ABT: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Spirit VHF-ABT exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Spirit VHF-ABT exhausts flue heat via Type B vent piping, lowering sealed efficiency vs condensing models.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Spirit VHF-ABT fit | Single-family replacement needing documented ENERGY STAR PD ID 4719610 with matching indoor air handler. |
| Skip Spirit VHF-ABT if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare Spirit VHF-ABT against Airco KHM-G3-*078-03* and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Spirit VHF-ABT compare with peer Residential Furnace units?
Spirit VHF-ABT holds #3,699 of 3,740 (42 tied at floor) out of 3,740 verified residential furnace models (-9.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 87.0% AFUE. Closest same-cohort alternatives include Airco KHM-G3-*078-03*.
Where is Spirit VHF-ABT compliant for 2026 US installation?
Spirit VHF-ABT: Meets 80%+ AFUE baseline under 10 CFR 430.32(e). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Spirit VHF-ABT model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Spirit VHF-ABT runs 574.7 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Spirit VHF-ABT cover?
Spirit VHF-ABT covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Spirit VHF-ABT handle extreme weather or cold snaps?
Spirit VHF-ABT delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Spirit VHF-ABT?
Spirit VHF-ABT specifies sealed combustion compliance (PD ID 4719610); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Spirit VHF-ABT reach 87.0% AFUE?
Peak 87.0% AFUE represents the top tested AHRI pairing for Spirit VHF-ABT (PD ID 4719610); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Spirit VHF-ABT?
Spirit VHF-ABT requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Airco KHM-G3-*078-03*.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.