Skip to main content
Residential Furnace · Ruud · 1 ENERGY STAR Combinations

Ruud R96TA0402317MSA — Residential Furnace Specifications

Ruud R96TA0402317MSA (Residential Furnace, PD ID 4693028) holds 1 ENERGY STAR certified SKU rated at 96.0% AFUE — #1,493 of 3,740 (804 tied at median), Equal to 96.0% AFUE category median. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Ruud R96TA0402317MSA — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.0% AFUE and Cohort Rank set at #1,493/3,740.

Thermal Efficiency
96.0% AFUE
Cohort Rank
#1,493/3,740
Verified Combos
1 SKU
Sample PD ID
4693028
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
Ruud R96TA0402317MSA Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. Ruud R96TA0402317MSA sits at 96.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 96.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566This series
96.3 - 97.7% AFUE1027Peer range
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Ruud R96TA0402317MSA residential equipment inspection. ThermalSpec Editorial Photography

How does Ruud R96TA0402317MSA rank across federal compliance and ENERGY STAR cohorts?

Ruud R96TA0402317MSA ranks #1,493 of 3,740 (tied with 803 others at 96.0% AFUE, more efficient than 38.6% of certified series) for Max AFUE (Equal to 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.0% AFUE (+16.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-24.

Ruud R96TA0402317MSA Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #1,493 of 3,740 (804 tied at median) Equal to 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (96.0% AFUE, +16.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does Ruud R96TA0402317MSA require?

Annual cost outputs combine Ruud R96TA0402317MSA's 96.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (96.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)520.8 therms/yr6,093 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$755/yrState range: $385 (ID) to $2,630 (HI)
Fuel Saved vs 80% AFUE Baseline104.2 therms/yr$151/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Ruud R96TA0402317MSA?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Ruud R96TA0402317MSA (PD ID 4693028).

R96TA0402317MSA Matched AHRI Coil — / 96.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Ruud R96TA0402317MSA, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Ruud R96TA0402317MSA: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Ruud R96TA0402317MSA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Ruud R96TA0402317MSA condensing combustion at 96.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Ruud R96TA0402317MSA fitSingle-family replacement needing documented ENERGY STAR PD ID 4693028 with matching indoor air handler.
Skip Ruud R96TA0402317MSA ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare Ruud R96TA0402317MSA against RUSSELL S96TA1152524MSA and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

RUSSELL S96TA1152524MSA

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R962V0403A17M4S

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R962V0603A17M4S

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Rheem R962V0703A17M4S

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Ruud R96TA0402317MSA compare with peer Residential Furnace units?

Ruud R96TA0402317MSA holds #1,493 of 3,740 (804 tied at median) out of 3,740 verified residential furnace models (Equal to 96.0% AFUE category median), spanning 1 certified SKU up to 96.0% AFUE. Closest same-cohort alternatives include RUSSELL S96TA1152524MSA.

DOE Regions

Where is Ruud R96TA0402317MSA compliant for 2026 US installation?

Ruud R96TA0402317MSA: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Ruud R96TA0402317MSA model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Ruud R96TA0402317MSA runs 520.8 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Ruud R96TA0402317MSA cover?

Ruud R96TA0402317MSA covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Ruud R96TA0402317MSA handle extreme weather or cold snaps?

Ruud R96TA0402317MSA delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Ruud R96TA0402317MSA?

Ruud R96TA0402317MSA specifies sealed combustion compliance (PD ID 4693028); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Ruud R96TA0402317MSA reach 96.0% AFUE?

Peak 96.0% AFUE represents the top tested AHRI pairing for Ruud R96TA0402317MSA (PD ID 4693028); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Ruud R96TA0402317MSA?

Ruud R96TA0402317MSA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include RUSSELL S96TA1152524MSA.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros