RUSSELL S972V0855A21UPS — Residential Furnace Specifications

RUSSELL S972V0855A21UPS (Residential Furnace, PD ID 4619720) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. RUSSELL S972V0855A21UPS — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

Thermal Efficiency
97.0% AFUE
Cohort Rank
#167/3,740
Verified Combos
1 SKU
Sample PD ID
4619720
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
RUSSELL S972V0855A21UPS Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. RUSSELL S972V0855A21UPS sits at 97.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 97.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566Peer range
96.3 - 97.7% AFUE1027This series
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
RUSSELL S972V0855A21UPS residential equipment inspection. ThermalSpec Editorial Photography

How does RUSSELL S972V0855A21UPS rank across federal compliance and ENERGY STAR cohorts?

RUSSELL S972V0855A21UPS ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-06-02.

RUSSELL S972V0855A21UPS Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #167 of 3,740 (Top 26.2%, 813 tied) +1.00% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does RUSSELL S972V0855A21UPS require?

Annual cost outputs combine RUSSELL S972V0855A21UPS's 97.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)515.5 therms/yr6,031 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$747/yrState range: $381 (ID) to $2,603 (HI)
Fuel Saved vs 80% AFUE Baseline109.5 therms/yr$159/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to RUSSELL S972V0855A21UPS?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for RUSSELL S972V0855A21UPS (PD ID 4619720).

S972V0855A21UPS Matched AHRI Coil — / 97.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on RUSSELL S972V0855A21UPS, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across RUSSELL S972V0855A21UPS: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for RUSSELL S972V0855A21UPS exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • RUSSELL S972V0855A21UPS condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal RUSSELL S972V0855A21UPS fitSingle-family replacement needing documented ENERGY STAR PD ID 4619720 with matching indoor air handler.
Skip RUSSELL S972V0855A21UPS ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare RUSSELL S972V0855A21UPS against MARATHERM R96MSN0802120A and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

MARATHERM R96MSN0802120A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

MARATHERM R96MSN0802120A*

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Midea MGV97U060B3A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Midea MGV97U080B3A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does RUSSELL S972V0855A21UPS compare with peer Residential Furnace units?

RUSSELL S972V0855A21UPS holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include MARATHERM R96MSN0802120A.

DOE Regions

Where is RUSSELL S972V0855A21UPS compliant for 2026 US installation?

RUSSELL S972V0855A21UPS: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does RUSSELL S972V0855A21UPS model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, RUSSELL S972V0855A21UPS runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does RUSSELL S972V0855A21UPS cover?

RUSSELL S972V0855A21UPS covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does RUSSELL S972V0855A21UPS handle extreme weather or cold snaps?

RUSSELL S972V0855A21UPS delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern RUSSELL S972V0855A21UPS?

RUSSELL S972V0855A21UPS specifies sealed combustion compliance (PD ID 4619720); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in RUSSELL S972V0855A21UPS reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for RUSSELL S972V0855A21UPS (PD ID 4619720); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to RUSSELL S972V0855A21UPS?

RUSSELL S972V0855A21UPS requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include MARATHERM R96MSN0802120A.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros