Payne PG97VTAA48060B (Residential Furnace, PD ID 4681095) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Payne PG97VTAA48060B — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

Thermal Efficiency
97.0% AFUE
Cohort Rank
#167/3,740
Verified Combos
1 SKU
Sample PD ID
4681095
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
Payne PG97VTAA48060B Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. Payne PG97VTAA48060B sits at 97.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 97.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566Peer range
96.3 - 97.7% AFUE1027This series
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Payne PG97VTAA48060B residential equipment inspection. ThermalSpec Editorial Photography

How does Payne PG97VTAA48060B rank across federal compliance and ENERGY STAR cohorts?

Payne PG97VTAA48060B ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.

Payne PG97VTAA48060B Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #167 of 3,740 (Top 26.2%, 813 tied) +1.00% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does Payne PG97VTAA48060B require?

Modeled utility figures for Payne PG97VTAA48060B (Payne) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max AFUE ratings.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)515.5 therms/yr6,031 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$747/yrState range: $381 (ID) to $2,603 (HI)
Fuel Saved vs 80% AFUE Baseline109.5 therms/yr$159/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Payne PG97VTAA48060B?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Payne PG97VTAA48060B (PD ID 4681095).

PG97VTAA48060B Matched AHRI Coil — / 97.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Payne PG97VTAA48060B, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Payne PG97VTAA48060B: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Payne PG97VTAA48060B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Payne PG97VTAA48060B condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Payne PG97VTAA48060B fitSingle-family replacement needing documented ENERGY STAR PD ID 4681095 with matching indoor air handler.
Skip Payne PG97VTAA48060B ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare Payne PG97VTAA48060B against Luxaire Z9VT060B12SMPC1 and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Luxaire Z9VT060B12SMPC1

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Luxaire Z9VT080B12SMPC1

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Luxaire Z9VT080C16SMPC1

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Luxaire Z9VT100C16SMPC1

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Payne PG97VTAA48060B compare with peer Residential Furnace units?

Payne PG97VTAA48060B holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Luxaire Z9VT060B12SMPC1.

DOE Regions

Where is Payne PG97VTAA48060B compliant for 2026 US installation?

Payne PG97VTAA48060B: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Payne PG97VTAA48060B model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Payne PG97VTAA48060B runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Payne PG97VTAA48060B cover?

Payne PG97VTAA48060B covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Payne PG97VTAA48060B handle extreme weather or cold snaps?

Payne PG97VTAA48060B delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Payne PG97VTAA48060B?

Payne PG97VTAA48060B specifies sealed combustion compliance (PD ID 4681095); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Payne PG97VTAA48060B reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for Payne PG97VTAA48060B (PD ID 4681095); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Payne PG97VTAA48060B?

Payne PG97VTAA48060B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Luxaire Z9VT060B12SMPC1.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros