Keeprite G96CTN0401410B — Residential Furnace Specifications
Keeprite G96CTN0401410B (Residential Furnace, PD ID 4681314) holds 1 ENERGY STAR certified SKU rated at 96.0% AFUE — #1,493 of 3,740 (804 tied at median), Equal to 96.0% AFUE category median. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Keeprite G96CTN0401410B — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.0% AFUE and Cohort Rank set at #1,493/3,740.
- Thermal Efficiency
- 96.0% AFUE
- Cohort Rank
- #1,493/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4681314
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | This series |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does Keeprite G96CTN0401410B rank across federal compliance and ENERGY STAR cohorts?
Keeprite G96CTN0401410B ranks #1,493 of 3,740 (tied with 803 others at 96.0% AFUE, more efficient than 38.6% of certified series) for Max AFUE (Equal to 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.0% AFUE (+16.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #1,493 of 3,740 (804 tied at median) | Equal to 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (96.0% AFUE, +16.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does Keeprite G96CTN0401410B require?
Modeled utility figures for Keeprite G96CTN0401410B (Keeprite) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max AFUE ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 520.8 therms/yr | 6,093 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $755/yr | State range: $385 (ID) to $2,630 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 104.2 therms/yr | $151/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Keeprite G96CTN0401410B?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Keeprite G96CTN0401410B (PD ID 4681314).
| G96CTN0401410B | Matched AHRI Coil | — | / 96.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Keeprite G96CTN0401410B, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Keeprite G96CTN0401410B: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Keeprite G96CTN0401410B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Keeprite G96CTN0401410B condensing combustion at 96.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Keeprite G96CTN0401410B fit | Single-family replacement needing documented ENERGY STAR PD ID 4681314 with matching indoor air handler. |
| Skip Keeprite G96CTN0401410B if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare Keeprite G96CTN0401410B against Gibson KG7TE-035D-E23AP* and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Keeprite G96CTN0401410B compare with peer Residential Furnace units?
Keeprite G96CTN0401410B holds #1,493 of 3,740 (804 tied at median) out of 3,740 verified residential furnace models (Equal to 96.0% AFUE category median), spanning 1 certified SKU up to 96.0% AFUE. Closest same-cohort alternatives include Gibson KG7TE-035D-E23AP*.
Where is Keeprite G96CTN0401410B compliant for 2026 US installation?
Keeprite G96CTN0401410B: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Keeprite G96CTN0401410B model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Keeprite G96CTN0401410B runs 520.8 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Keeprite G96CTN0401410B cover?
Keeprite G96CTN0401410B covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Keeprite G96CTN0401410B handle extreme weather or cold snaps?
Keeprite G96CTN0401410B delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Keeprite G96CTN0401410B?
Keeprite G96CTN0401410B specifies sealed combustion compliance (PD ID 4681314); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Keeprite G96CTN0401410B reach 96.0% AFUE?
Peak 96.0% AFUE represents the top tested AHRI pairing for Keeprite G96CTN0401410B (PD ID 4681314); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Keeprite G96CTN0401410B?
Keeprite G96CTN0401410B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Gibson KG7TE-035D-E23AP*.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.