GUARDIAN BY JOHNSON CONTROLS Furnaces — ENERGY STAR Certified Models
GUARDIAN BY JOHNSON CONTROLS certifies 15 furnaces models across 15 AHRI combinations, led by RG19026A08MPS1 at 97.0% AFUE against the 96.0% AFUE category median across Residential capacities. GUARDIAN BY JOHNSON CONTROLS Furnaces — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 15 and Rating Span set at 95.0% AFUE - 97.0% AFUE.
- Certified Models
- 15
- Rating Span
- 95.0% AFUE - 97.0% AFUE
- Capacity Range
- Residential capacities
- AHRI Combinations
- 15
- Cold Climate Units
- 0
- Category Median
- 96.0% AFUE
How does GUARDIAN BY JOHNSON CONTROLS's furnaces portfolio cover capacity, refrigerants, and safety?
GUARDIAN BY JOHNSON CONTROLS covers Residential capacities in furnaces across 15 canonical models and 15 AHRI combinations, with 0 Cold Climate certified models and Gas / Propane combustion. Ratings span 95.0% AFUE up to 97.0% AFUE (category median 96.0% AFUE, certified through 2026-09-21). CPSC records show 0 residential HVAC recall notices matching GUARDIAN BY JOHNSON CONTROLS; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in GUARDIAN BY JOHNSON CONTROLS Furnaces — ENERGY STAR Certified Models?
Compare all 15 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1 | 97.0% AFUE | Condensing | Natural Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19040A10MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19060A10MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19060B12MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19080B12MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19080C16MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19080C20MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19100C16MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19100C20MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS RG19120D20MPS1 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS MM9E060B12MP11 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS MM9E080B12MP11 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS MM9E080C16MP11 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS MM9E080C20MP11 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| GUARDIAN BY JOHNSON CONTROLS MM9E100C16MP11 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
Which top GUARDIAN BY JOHNSON CONTROLS furnaces anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1
GUARDIAN BY JOHNSON CONTROLS RG19040A10MPS1
GUARDIAN BY JOHNSON CONTROLS RG19060A10MPS1
GUARDIAN BY JOHNSON CONTROLS RG19060B12MPS1
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GUARDIAN BY JOHNSON CONTROLS Furnaces, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across GUARDIAN BY JOHNSON CONTROLS: 95.0% AFUE entry units differ substantially from flagship RG19026A08MPS1 (97.0% AFUE).
- Verify indoor coil AHRI pairing on PD ID 4707378 and 4726559 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for GUARDIAN BY JOHNSON CONTROLS | Homes matched to Residential capacities seeking Gas / Propane combustion compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which GUARDIAN BY JOHNSON CONTROLS furnaces model reaches the highest 97.0% AFUE rating?
RG19026A08MPS1 tops GUARDIAN BY JOHNSON CONTROLS's 15 ENERGY STAR furnaces models at 97.0% AFUE across 1 AHRI matches (PD ID 4707378).
How broad is GUARDIAN BY JOHNSON CONTROLS's furnaces efficiency and BTU range?
GUARDIAN BY JOHNSON CONTROLS spans 95.0% AFUE (MM9E100C16MP11) up to 97.0% AFUE (RG19026A08MPS1) across Residential capacities, compared with the 96.0% AFUE category median.
How many AHRI combinations support GUARDIAN BY JOHNSON CONTROLS furnaces?
Current ENERGY STAR datasets document 15 verified indoor-outdoor AHRI combinations distributed across 15 canonical GUARDIAN BY JOHNSON CONTROLS models.
What refrigerants or fuels power GUARDIAN BY JOHNSON CONTROLS furnaces?
GUARDIAN BY JOHNSON CONTROLS furnaces listings record Gas / Propane combustion, with 0 Cold Climate certified models inside the furnaces cohort.
Where are GUARDIAN BY JOHNSON CONTROLS furnaces compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to GUARDIAN BY JOHNSON CONTROLS residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing GUARDIAN BY JOHNSON CONTROLS; verify model serial prefixes at /recalls/ before installation or service.
Do GUARDIAN BY JOHNSON CONTROLS furnaces receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for GUARDIAN BY JOHNSON CONTROLS in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 4707378.
How should homeowners select among GUARDIAN BY JOHNSON CONTROLS's 15 furnaces models?
Match GUARDIAN BY JOHNSON CONTROLS model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.