Skip to main content
Residential Furnace · Goodman · 1 ENERGY STAR Combinations

Goodman GR9S960603BU — Residential Furnace Specifications

Goodman GR9S960603BU (Residential Furnace, PD ID 4593601) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Goodman GR9S960603BU — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

Thermal Efficiency
97.0% AFUE
Cohort Rank
#167/3,740
Verified Combos
1 SKU
Sample PD ID
4593601
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
Goodman GR9S960603BU Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. Goodman GR9S960603BU sits at 97.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 97.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566Peer range
96.3 - 97.7% AFUE1027This series
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Goodman GR9S960603BU residential equipment inspection. ThermalSpec Editorial Photography

How does Goodman GR9S960603BU rank across federal compliance and ENERGY STAR cohorts?

Goodman GR9S960603BU ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-04-27.

Goodman GR9S960603BU Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #167 of 3,740 (Top 26.2%, 813 tied) +1.00% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does Goodman GR9S960603BU require?

Annual cost outputs combine Goodman GR9S960603BU's 97.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)515.5 therms/yr6,031 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$747/yrState range: $381 (ID) to $2,603 (HI)
Fuel Saved vs 80% AFUE Baseline109.5 therms/yr$159/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Goodman GR9S960603BU?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Goodman GR9S960603BU (PD ID 4593601).

GR9S960603BU Matched AHRI Coil — / 97.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Goodman GR9S960603BU, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Goodman GR9S960603BU: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Goodman GR9S960603BU exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Goodman GR9S960603BU condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Goodman GR9S960603BU fitSingle-family replacement needing documented ENERGY STAR PD ID 4593601 with matching indoor air handler.
Skip Goodman GR9S960603BU ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare Goodman GR9S960603BU against Fujitsu FF97TV307017UPS*A and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Fujitsu FF97TV307017UPS*A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Fujitsu FF97TV507021UPS*A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Fujitsu FF97TV508521UPS*A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Fujitsu FF97TV510021UPS*A

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Goodman GR9S960603BU compare with peer Residential Furnace units?

Goodman GR9S960603BU holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Fujitsu FF97TV307017UPS*A.

DOE Regions

Where is Goodman GR9S960603BU compliant for 2026 US installation?

Goodman GR9S960603BU: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Goodman GR9S960603BU model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Goodman GR9S960603BU runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Goodman GR9S960603BU cover?

Goodman GR9S960603BU covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Goodman GR9S960603BU handle extreme weather or cold snaps?

Goodman GR9S960603BU delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Goodman GR9S960603BU?

Goodman GR9S960603BU specifies sealed combustion compliance (PD ID 4593601); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Goodman GR9S960603BU reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for Goodman GR9S960603BU (PD ID 4593601); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Goodman GR9S960603BU?

Goodman GR9S960603BU requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Fujitsu FF97TV307017UPS*A.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)