Skip to main content
Residential Furnace · GE · 1 ENERGY STAR Combinations

GE NF96D070S4BR — Residential Furnace Specifications

GE NF96D070S4BR (Residential Furnace, PD ID 4617006) holds 1 ENERGY STAR certified SKU rated at 96.0% AFUE — #1,493 of 3,740 (804 tied at median), Equal to 96.0% AFUE category median. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. GE NF96D070S4BR — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.0% AFUE and Cohort Rank set at #1,493/3,740.

Thermal Efficiency
96.0% AFUE
Cohort Rank
#1,493/3,740
Verified Combos
1 SKU
Sample PD ID
4617006
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
GE NF96D070S4BR Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. GE NF96D070S4BR sits at 96.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 96.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566This series
96.3 - 97.7% AFUE1027Peer range
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
GE NF96D070S4BR residential equipment inspection. ThermalSpec Editorial Photography

How does GE NF96D070S4BR rank across federal compliance and ENERGY STAR cohorts?

GE NF96D070S4BR ranks #1,493 of 3,740 (tied with 803 others at 96.0% AFUE, more efficient than 38.6% of certified series) for Max AFUE (Equal to 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.0% AFUE (+16.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-05-27.

GE NF96D070S4BR Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #1,493 of 3,740 (804 tied at median) Equal to 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (96.0% AFUE, +16.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does GE NF96D070S4BR require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GE NF96D070S4BR estimates reflect 1 certified SKU combination tested under PD ID 4617006.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (96.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)520.8 therms/yr6,093 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$755/yrState range: $385 (ID) to $2,630 (HI)
Fuel Saved vs 80% AFUE Baseline104.2 therms/yr$151/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to GE NF96D070S4BR?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GE NF96D070S4BR (PD ID 4617006).

NF96D070S4BR Matched AHRI Coil — / 96.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on GE NF96D070S4BR, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across GE NF96D070S4BR: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for GE NF96D070S4BR exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • GE NF96D070S4BR condensing combustion at 96.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal GE NF96D070S4BR fitSingle-family replacement needing documented ENERGY STAR PD ID 4617006 with matching indoor air handler.
Skip GE NF96D070S4BR ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare GE NF96D070S4BR against Friedrich FR962V1155A24M4S and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Friedrich FR962V1155A24M4S

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Friedrich FR96TA0402317MSA

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Friedrich FR96TA0602317MSA

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Friedrich FR96TA0702317MSA

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does GE NF96D070S4BR compare with peer Residential Furnace units?

GE NF96D070S4BR holds #1,493 of 3,740 (804 tied at median) out of 3,740 verified residential furnace models (Equal to 96.0% AFUE category median), spanning 1 certified SKU up to 96.0% AFUE. Closest same-cohort alternatives include Friedrich FR962V1155A24M4S.

DOE Regions

Where is GE NF96D070S4BR compliant for 2026 US installation?

GE NF96D070S4BR: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does GE NF96D070S4BR model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, GE NF96D070S4BR runs 520.8 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does GE NF96D070S4BR cover?

GE NF96D070S4BR covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does GE NF96D070S4BR handle extreme weather or cold snaps?

GE NF96D070S4BR delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern GE NF96D070S4BR?

GE NF96D070S4BR specifies sealed combustion compliance (PD ID 4617006); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in GE NF96D070S4BR reach 96.0% AFUE?

Peak 96.0% AFUE represents the top tested AHRI pairing for GE NF96D070S4BR (PD ID 4617006); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to GE NF96D070S4BR?

GE NF96D070S4BR requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Friedrich FR962V1155A24M4S.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.