GE NF95X060S3BR — Residential Furnace Specifications
GE NF95X060S3BR (Residential Furnace, PD ID 4619674) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #2,297 of 3,740 (1,402 tied, beats 1.1% of peers), -1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. GE NF95X060S3BR — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #2,297/3,740.
- Thermal Efficiency
- 95.0% AFUE
- Cohort Rank
- #2,297/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4619674
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | This series |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does GE NF95X060S3BR rank across federal compliance and ENERGY STAR cohorts?
GE NF95X060S3BR ranks #2,297 of 3,740 (tied with 1,401 others at 95.0% AFUE, more efficient than 1.1% of certified series) for Max AFUE (-1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-06-02.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) | -1.00% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (95.0% AFUE, +15.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does GE NF95X060S3BR require?
Annual cost outputs combine GE NF95X060S3BR's 95.0% AFUE rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 526.3 therms/yr | 6,158 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $763/yr | State range: $389 (ID) to $2,658 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 98.7 therms/yr | $143/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to GE NF95X060S3BR?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GE NF95X060S3BR (PD ID 4619674).
| NF95X060S3BR | Matched AHRI Coil | — | / 95.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GE NF95X060S3BR, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GE NF95X060S3BR: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GE NF95X060S3BR exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- GE NF95X060S3BR condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GE NF95X060S3BR fit | Single-family replacement needing documented ENERGY STAR PD ID 4619674 with matching indoor air handler. |
| Skip GE NF95X060S3BR if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare GE NF95X060S3BR against Friedrich FR951V0855A21M4S and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GE NF95X060S3BR compare with peer Residential Furnace units?
GE NF95X060S3BR holds #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) out of 3,740 verified residential furnace models (-1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include Friedrich FR951V0855A21M4S.
Where is GE NF95X060S3BR compliant for 2026 US installation?
GE NF95X060S3BR: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GE NF95X060S3BR model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GE NF95X060S3BR runs 526.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does GE NF95X060S3BR cover?
GE NF95X060S3BR covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GE NF95X060S3BR handle extreme weather or cold snaps?
GE NF95X060S3BR delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern GE NF95X060S3BR?
GE NF95X060S3BR specifies sealed combustion compliance (PD ID 4619674); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GE NF95X060S3BR reach 95.0% AFUE?
Peak 95.0% AFUE represents the top tested AHRI pairing for GE NF95X060S3BR (PD ID 4619674); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GE NF95X060S3BR?
GE NF95X060S3BR requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Friedrich FR951V0855A21M4S.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.