BROCK PG96MSAA36040B — Residential Furnace Specifications
BROCK PG96MSAA36040B (Residential Furnace, PD ID 4673843) holds 1 ENERGY STAR certified SKU rated at 96.7% AFUE — #980 of 3,740 (Top 29.7%, 131 tied), +0.70% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. BROCK PG96MSAA36040B — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.7% AFUE and Cohort Rank set at #980/3,740.
- Thermal Efficiency
- 96.7% AFUE
- Cohort Rank
- #980/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4673843
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | This series |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does BROCK PG96MSAA36040B rank across federal compliance and ENERGY STAR cohorts?
BROCK PG96MSAA36040B ranks #980 of 3,740 (tied with 130 others at 96.7% AFUE, top 29.7%, more efficient than 70.3% of certified series) for Max AFUE (+0.70% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.7% AFUE (+16.7 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-07-20.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #980 of 3,740 (Top 29.7%, 131 tied) | +0.70% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (96.7% AFUE, +16.7 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does BROCK PG96MSAA36040B require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, BROCK PG96MSAA36040B estimates reflect 1 certified SKU combination tested under PD ID 4673843.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 517.1 therms/yr | 6,050 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $750/yr | State range: $383 (ID) to $2,611 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 107.9 therms/yr | $156/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to BROCK PG96MSAA36040B?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for BROCK PG96MSAA36040B (PD ID 4673843).
| PG96MSAA36040B | Matched AHRI Coil | — | / 96.7% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BROCK PG96MSAA36040B, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BROCK PG96MSAA36040B: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for BROCK PG96MSAA36040B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BROCK PG96MSAA36040B condensing combustion at 96.7% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BROCK PG96MSAA36040B fit | Single-family replacement needing documented ENERGY STAR PD ID 4673843 with matching indoor air handler. |
| Skip BROCK PG96MSAA36040B if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare BROCK PG96MSAA36040B against ACIQ G96VTN0802120B and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BROCK PG96MSAA36040B compare with peer Residential Furnace units?
BROCK PG96MSAA36040B holds #980 of 3,740 (Top 29.7%, 131 tied) out of 3,740 verified residential furnace models (+0.70% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 96.7% AFUE. Closest same-cohort alternatives include ACIQ G96VTN0802120B.
Where is BROCK PG96MSAA36040B compliant for 2026 US installation?
BROCK PG96MSAA36040B: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BROCK PG96MSAA36040B model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BROCK PG96MSAA36040B runs 517.1 therms/yr across standard cooling/heating hours.
What capacity band and airflow does BROCK PG96MSAA36040B cover?
BROCK PG96MSAA36040B covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BROCK PG96MSAA36040B handle extreme weather or cold snaps?
BROCK PG96MSAA36040B delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern BROCK PG96MSAA36040B?
BROCK PG96MSAA36040B specifies sealed combustion compliance (PD ID 4673843); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in BROCK PG96MSAA36040B reach 96.7% AFUE?
Peak 96.7% AFUE represents the top tested AHRI pairing for BROCK PG96MSAA36040B (PD ID 4673843); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BROCK PG96MSAA36040B?
BROCK PG96MSAA36040B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ G96VTN0802120B.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages