American Standard S9V2B060U4VS*** — Residential Furnace Specifications
American Standard S9V2B060U4VS*** (Residential Furnace, PD ID 4674192) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. American Standard S9V2B060U4VS*** — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.
- Thermal Efficiency
- 97.0% AFUE
- Cohort Rank
- #167/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4674192
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | This series |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does American Standard S9V2B060U4VS*** rank across federal compliance and ENERGY STAR cohorts?
American Standard S9V2B060U4VS*** ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #167 of 3,740 (Top 26.2%, 813 tied) | +1.00% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does American Standard S9V2B060U4VS*** require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, American Standard S9V2B060U4VS*** estimates reflect 1 certified SKU combination tested under PD ID 4674192.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 515.5 therms/yr | 6,031 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $747/yr | State range: $381 (ID) to $2,603 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 109.5 therms/yr | $159/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to American Standard S9V2B060U4VS***?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for American Standard S9V2B060U4VS*** (PD ID 4674192).
| S9V2B060U4VS*** | Matched AHRI Coil | — | / 97.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on American Standard S9V2B060U4VS***, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across American Standard S9V2B060U4VS***: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for American Standard S9V2B060U4VS*** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- American Standard S9V2B060U4VS*** condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal American Standard S9V2B060U4VS*** fit | Single-family replacement needing documented ENERGY STAR PD ID 4674192 with matching indoor air handler. |
| Skip American Standard S9V2B060U4VS*** if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare American Standard S9V2B060U4VS*** against Airquest N96MSN0802120A and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does American Standard S9V2B060U4VS*** compare with peer Residential Furnace units?
American Standard S9V2B060U4VS*** holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Airquest N96MSN0802120A.
Where is American Standard S9V2B060U4VS*** compliant for 2026 US installation?
American Standard S9V2B060U4VS***: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does American Standard S9V2B060U4VS*** model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, American Standard S9V2B060U4VS*** runs 515.5 therms/yr across standard cooling/heating hours.
What capacity band and airflow does American Standard S9V2B060U4VS*** cover?
American Standard S9V2B060U4VS*** covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does American Standard S9V2B060U4VS*** handle extreme weather or cold snaps?
American Standard S9V2B060U4VS*** delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern American Standard S9V2B060U4VS***?
American Standard S9V2B060U4VS*** specifies sealed combustion compliance (PD ID 4674192); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in American Standard S9V2B060U4VS*** reach 97.0% AFUE?
Peak 97.0% AFUE represents the top tested AHRI pairing for American Standard S9V2B060U4VS*** (PD ID 4674192); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to American Standard S9V2B060U4VS***?
American Standard S9V2B060U4VS*** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Airquest N96MSN0802120A.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.