Amana ARVM970803BN — Residential Furnace Specifications
Amana ARVM970803BN (Residential Furnace, PD ID 4612095) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Amana ARVM970803BN — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.
- Thermal Efficiency
- 97.0% AFUE
- Cohort Rank
- #167/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4612095
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | This series |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does Amana ARVM970803BN rank across federal compliance and ENERGY STAR cohorts?
Amana ARVM970803BN ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-05-12.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #167 of 3,740 (Top 26.2%, 813 tied) | +1.00% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does Amana ARVM970803BN require?
Annual cost outputs combine Amana ARVM970803BN's 97.0% AFUE rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 515.5 therms/yr | 6,031 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $747/yr | State range: $381 (ID) to $2,603 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 109.5 therms/yr | $159/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Amana ARVM970803BN?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Amana ARVM970803BN (PD ID 4612095).
| ARVM970803BN | Matched AHRI Coil | — | / 97.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Amana ARVM970803BN, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Amana ARVM970803BN: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Amana ARVM970803BN exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Amana ARVM970803BN condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Amana ARVM970803BN fit | Single-family replacement needing documented ENERGY STAR PD ID 4612095 with matching indoor air handler. |
| Skip Amana ARVM970803BN if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare Amana ARVM970803BN against Airquest G97VTN0601716A and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Amana ARVM970803BN compare with peer Residential Furnace units?
Amana ARVM970803BN holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Airquest G97VTN0601716A.
Where is Amana ARVM970803BN compliant for 2026 US installation?
Amana ARVM970803BN: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Amana ARVM970803BN model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Amana ARVM970803BN runs 515.5 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Amana ARVM970803BN cover?
Amana ARVM970803BN covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Amana ARVM970803BN handle extreme weather or cold snaps?
Amana ARVM970803BN delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Amana ARVM970803BN?
Amana ARVM970803BN specifies sealed combustion compliance (PD ID 4612095); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Amana ARVM970803BN reach 97.0% AFUE?
Peak 97.0% AFUE represents the top tested AHRI pairing for Amana ARVM970803BN (PD ID 4612095); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Amana ARVM970803BN?
Amana ARVM970803BN requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Airquest G97VTN0601716A.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.