Airquest N96MSN0601412A — Residential Furnace Specifications
Airquest N96MSN0601412A (Residential Furnace, PD ID 4677441) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #2,297 of 3,740 (1,402 tied, beats 1.1% of peers), -1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Airquest N96MSN0601412A — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #2,297/3,740.
- Thermal Efficiency
- 95.0% AFUE
- Cohort Rank
- #2,297/3,740
- Verified Combos
- 1 SKU
- Sample PD ID
- 4677441
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | This series |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |
How does Airquest N96MSN0601412A rank across federal compliance and ENERGY STAR cohorts?
Airquest N96MSN0601412A ranks #2,297 of 3,740 (tied with 1,401 others at 95.0% AFUE, more efficient than 1.1% of certified series) for Max AFUE (-1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-07-28.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) | -1.00% AFUE vs 96.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Gas Furnace Minimum | PASS | Meets or exceeds federal 80% AFUE floor (95.0% AFUE, +15.0 pts above minimum) |
| Condensing Secondary Heat Exchanger Tier | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| Domestic Hot Water Integration | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |
How much annual energy and operating cost does Airquest N96MSN0601412A require?
Annual cost outputs combine Airquest N96MSN0601412A's 95.0% AFUE rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 526.3 therms/yr | 6,158 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $763/yr | State range: $389 (ID) to $2,658 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 98.7 therms/yr | $143/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Airquest N96MSN0601412A?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Airquest N96MSN0601412A (PD ID 4677441).
| N96MSN0601412A | Matched AHRI Coil | — | / 95.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Airquest N96MSN0601412A, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Airquest N96MSN0601412A: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Airquest N96MSN0601412A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Airquest N96MSN0601412A condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Airquest N96MSN0601412A fit | Single-family replacement needing documented ENERGY STAR PD ID 4677441 with matching indoor air handler. |
| Skip Airquest N96MSN0601412A if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential furnace models deliver similar efficiency?
Compare Airquest N96MSN0601412A against Amana AD9S961005CN and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Airquest N96MSN0601412A compare with peer Residential Furnace units?
Airquest N96MSN0601412A holds #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) out of 3,740 verified residential furnace models (-1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include Amana AD9S961005CN.
Where is Airquest N96MSN0601412A compliant for 2026 US installation?
Airquest N96MSN0601412A: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Airquest N96MSN0601412A model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Airquest N96MSN0601412A runs 526.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Airquest N96MSN0601412A cover?
Airquest N96MSN0601412A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Airquest N96MSN0601412A handle extreme weather or cold snaps?
Airquest N96MSN0601412A delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Airquest N96MSN0601412A?
Airquest N96MSN0601412A specifies sealed combustion compliance (PD ID 4677441); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Airquest N96MSN0601412A reach 95.0% AFUE?
Peak 95.0% AFUE represents the top tested AHRI pairing for Airquest N96MSN0601412A (PD ID 4677441); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Airquest N96MSN0601412A?
Airquest N96MSN0601412A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Amana AD9S961005CN.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.