Skip to main content
Residential Furnace · Airquest · 1 ENERGY STAR Combinations

Airquest N96MSM0601716A*D — Residential Furnace Specifications

Airquest N96MSM0601716A*D (Residential Furnace, PD ID 4673710) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #2,297 of 3,740 (1,402 tied, beats 1.1% of peers), -1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Airquest N96MSM0601716A*D — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #2,297/3,740.

Thermal Efficiency
95.0% AFUE
Cohort Rank
#2,297/3,740
Verified Combos
1 SKU
Sample PD ID
4673710
Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)
Airquest N96MSM0601716A*D Residential Furnace Efficiency Spread Distribution Distribution of 3740 certified series from 87.0 to 99.0% AFUE. Airquest N96MSM0601716A*D sits at 95.0% AFUE; typical midpoint is 96.0% AFUE. 42 87.0 0 88.3 0 89.7 0 91.0 0 92.3 0 93.7 2566 95.0 1027 96.3 105 97.7 Median 96.0% AFUE This model: 95.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.3% AFUE42Peer range
88.3 - 89.7% AFUE0Peer range
89.7 - 91.0% AFUE0Peer range
91.0 - 92.3% AFUE0Peer range
92.3 - 93.7% AFUE0Peer range
93.7 - 95.0% AFUE0Peer range
95.0 - 96.3% AFUE2566This series
96.3 - 97.7% AFUE1027Peer range
97.7 - 99.0% AFUE105Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Airquest N96MSM0601716A*D residential equipment inspection. ThermalSpec Editorial Photography

How does Airquest N96MSM0601716A*D rank across federal compliance and ENERGY STAR cohorts?

Airquest N96MSM0601716A*D ranks #2,297 of 3,740 (tied with 1,401 others at 95.0% AFUE, more efficient than 1.1% of certified series) for Max AFUE (-1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.

Airquest N96MSM0601716A*D Cohort Metrics vs. Residential Furnace Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) -1.00% AFUE vs 96.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Gas Furnace Minimum PASS Meets or exceeds federal 80% AFUE floor (95.0% AFUE, +15.0 pts above minimum)
Condensing Secondary Heat Exchanger Tier CONDENSING >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap
Domestic Hot Water Integration SPACE HEAT ONLY ENERGY STAR dataset flag: can_integrate_hot_water_heating

How much annual energy and operating cost does Airquest N96MSM0601716A*D require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Airquest N96MSM0601716A*D estimates reflect 1 certified SKU combination tested under PD ID 4673710.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (95.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)526.3 therms/yr6,158 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$763/yrState range: $389 (ID) to $2,658 (HI)
Fuel Saved vs 80% AFUE Baseline98.7 therms/yr$143/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Airquest N96MSM0601716A*D?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Airquest N96MSM0601716A*D (PD ID 4673710).

N96MSM0601716A*D Matched AHRI Coil — / 95.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Airquest N96MSM0601716A*D, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Airquest N96MSM0601716A*D: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Airquest N96MSM0601716A*D exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Airquest N96MSM0601716A*D condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Airquest N96MSM0601716A*D fitSingle-family replacement needing documented ENERGY STAR PD ID 4673710 with matching indoor air handler.
Skip Airquest N96MSM0601716A*D ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential furnace models deliver similar efficiency?

Compare Airquest N96MSM0601716A*D against Amana AD9S961005CN and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

Amana AD9S961005CN

95.0% AFUE · Natural Gas, Propane Gas · 1 combos

Amana AD9S961205DN

95.0% AFUE · Natural Gas, Propane Gas · 1 combos

Amana AR9S960803BN

95.0% AFUE · Natural Gas, Propane Gas · 1 combos

Amana AR9S961205DN

95.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Airquest N96MSM0601716A*D compare with peer Residential Furnace units?

Airquest N96MSM0601716A*D holds #2,297 of 3,740 (1,402 tied, beats 1.1% of peers) out of 3,740 verified residential furnace models (-1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include Amana AD9S961005CN.

DOE Regions

Where is Airquest N96MSM0601716A*D compliant for 2026 US installation?

Airquest N96MSM0601716A*D: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Airquest N96MSM0601716A*D model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Airquest N96MSM0601716A*D runs 526.3 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Airquest N96MSM0601716A*D cover?

Airquest N96MSM0601716A*D covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Airquest N96MSM0601716A*D handle extreme weather or cold snaps?

Airquest N96MSM0601716A*D delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Airquest N96MSM0601716A*D?

Airquest N96MSM0601716A*D specifies sealed combustion compliance (PD ID 4673710); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Airquest N96MSM0601716A*D reach 95.0% AFUE?

Peak 95.0% AFUE represents the top tested AHRI pairing for Airquest N96MSM0601716A*D (PD ID 4673710); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Airquest N96MSM0601716A*D?

Airquest N96MSM0601716A*D requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Amana AD9S961005CN.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Furnaces Dataset (i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros