Weil-McLain AB-80-* — Residential Boiler Specifications
Weil-McLain AB-80-* (Residential Boiler, PD ID 2323473) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #53 of 663 (402 tied at median), Equal to 95.0% AFUE category median. Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). Weil-McLain AB-80-* — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #53/663.
- Thermal Efficiency
- 95.0% AFUE
- Cohort Rank
- #53/663
- Verified Combos
- 1 SKU
- Sample PD ID
- 2323473
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.1% AFUE | 148 | Peer range |
| 88.1 - 89.2% AFUE | 0 | Peer range |
| 89.2 - 90.3% AFUE | 22 | Peer range |
| 90.3 - 91.4% AFUE | 13 | Peer range |
| 91.4 - 92.6% AFUE | 3 | Peer range |
| 92.6 - 93.7% AFUE | 4 | Peer range |
| 93.7 - 94.8% AFUE | 19 | Peer range |
| 94.8 - 95.9% AFUE | 402 | This series |
| 95.9 - 97.0% AFUE | 52 | Peer range |
How does Weil-McLain AB-80-* rank across federal compliance and ENERGY STAR cohorts?
Weil-McLain AB-80-* ranks #53 of 663 (tied with 401 others at 95.0% AFUE, more efficient than 31.5% of certified series) for Max AFUE (Equal to 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2021-11-08.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #53 of 663 (402 tied at median) | Equal to 95.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Residential Boiler Minimum | PASS | Rated 95.0% AFUE vs 84% federal gas hot-water boiler baseline |
| Condensing Hydronic Design | CONDENSING | Extracts latent flue heat below 140F return water temp |
How much annual energy and operating cost does Weil-McLain AB-80-* require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Weil-McLain AB-80-* estimates reflect 1 certified SKU combination tested under PD ID 2323473.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 526.3 therms/yr | 6,158 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $763/yr | State range: $389 (ID) to $2,658 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 98.7 therms/yr | $143/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Weil-McLain AB-80-*?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Weil-McLain AB-80-* (PD ID 2323473).
| AB-80-* | Matched AHRI Coil | — | / 95.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Weil-McLain AB-80-*, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Weil-McLain AB-80-*: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Weil-McLain AB-80-* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Weil-McLain AB-80-* condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Weil-McLain AB-80-* fit | Single-family replacement needing documented ENERGY STAR PD ID 2323473 with matching indoor air handler. |
| Skip Weil-McLain AB-80-* if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential boiler models deliver similar efficiency?
Compare Weil-McLain AB-80-* against Energy Kinetics Accel CS EK2C 150 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Weil-McLain AB-80-* compare with peer Residential Boiler units?
Weil-McLain AB-80-* holds #53 of 663 (402 tied at median) out of 663 verified residential boiler models (Equal to 95.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include Energy Kinetics Accel CS EK2C 150.
Where is Weil-McLain AB-80-* compliant for 2026 US installation?
Weil-McLain AB-80-*: Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Weil-McLain AB-80-* model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Weil-McLain AB-80-* runs 526.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Weil-McLain AB-80-* cover?
Weil-McLain AB-80-* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Weil-McLain AB-80-* handle extreme weather or cold snaps?
Weil-McLain AB-80-* delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Weil-McLain AB-80-*?
Weil-McLain AB-80-* specifies sealed combustion compliance (PD ID 2323473); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Weil-McLain AB-80-* reach 95.0% AFUE?
Peak 95.0% AFUE represents the top tested AHRI pairing for Weil-McLain AB-80-* (PD ID 2323473); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Weil-McLain AB-80-*?
Weil-McLain AB-80-* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Energy Kinetics Accel CS EK2C 150.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages