Radiant Boilers — ENERGY STAR Certified Models
Rated from 96.0% AFUE to 96.0% AFUE over 7 certified combinations, Radiant's 7 residential boilers models use Gas / Propane combustion. Radiant Boilers — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 7 and Rating Span set at 96.0% AFUE - 96.0% AFUE. Values trace to primary federal, state, or OEM filings supporting Radiant Boilers — ENERGY STAR Certified Models across single-family housing.
- Certified Models
- 7
- Rating Span
- 96.0% AFUE - 96.0% AFUE
- Capacity Range
- Residential capacities
- AHRI Combinations
- 7
- Cold Climate Units
- 0
- Category Median
- 95.0% AFUE
How does Radiant's boilers portfolio cover capacity, refrigerants, and safety?
Radiant covers Residential capacities in boilers across 7 canonical models and 7 AHRI combinations, with 0 Cold Climate certified models and Gas / Propane combustion. Ratings span 96.0% AFUE up to 96.0% AFUE (category median 95.0% AFUE, certified through 2022-09-14). CPSC records show 0 residential HVAC recall notices matching Radiant; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in Radiant Boilers — ENERGY STAR Certified Models?
Compare all 7 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| Radiant R1K 34/B | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R1K 55 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R2K 24 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R2K 34 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R2K 55 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R2KA 24/20 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| Radiant R2KA 34/20 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
Which top Radiant boilers anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
Radiant R1K 34/B
Radiant R1K 55
Radiant R2K 24
Radiant R2K 34
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Radiant Boilers, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across Radiant: 96.0% AFUE entry units differ substantially from flagship R1K 34/B (96.0% AFUE).
- Verify indoor coil AHRI pairing on PD ID 2401463 and 2401462 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for Radiant | Homes matched to Residential capacities seeking Gas / Propane combustion compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which Radiant boilers model reaches the highest 96.0% AFUE rating?
R1K 34/B tops Radiant's 7 ENERGY STAR boilers models at 96.0% AFUE across 1 AHRI matches (PD ID 2401463).
How broad is Radiant's boilers efficiency and BTU range?
Radiant spans 96.0% AFUE (R2KA 34/20) up to 96.0% AFUE (R1K 34/B) across Residential capacities, compared with the 95.0% AFUE category median.
How many AHRI combinations support Radiant boilers?
Current ENERGY STAR datasets document 7 verified indoor-outdoor AHRI combinations distributed across 7 canonical Radiant models.
What refrigerants or fuels power Radiant boilers?
Radiant boilers listings record Gas / Propane combustion, with 0 Cold Climate certified models inside the boilers cohort.
Where are Radiant boilers compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to Radiant residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing Radiant; verify model serial prefixes at /recalls/ before installation or service.
Do Radiant boilers receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Radiant in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2401463.
How should homeowners select among Radiant's 7 boilers models?
Match Radiant model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.