PurePro P3ES — Residential Boiler Specifications
PurePro P3ES (Residential Boiler, PD ID 2344438) holds 1 ENERGY STAR certified SKU rated at 87.0% AFUE — #518 of 663 (146 tied at floor), -8.00% AFUE. ENERGY STAR certified residential boiler (87.0% AFUE). PurePro P3ES — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 87.0% AFUE and Cohort Rank set at #518/663.
- Thermal Efficiency
- 87.0% AFUE
- Cohort Rank
- #518/663
- Verified Combos
- 1 SKU
- Sample PD ID
- 2344438
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.1% AFUE | 148 | This series |
| 88.1 - 89.2% AFUE | 0 | Peer range |
| 89.2 - 90.3% AFUE | 22 | Peer range |
| 90.3 - 91.4% AFUE | 13 | Peer range |
| 91.4 - 92.6% AFUE | 3 | Peer range |
| 92.6 - 93.7% AFUE | 4 | Peer range |
| 93.7 - 94.8% AFUE | 19 | Peer range |
| 94.8 - 95.9% AFUE | 402 | Peer range |
| 95.9 - 97.0% AFUE | 52 | Peer range |
How does PurePro P3ES rank across federal compliance and ENERGY STAR cohorts?
PurePro P3ES ties with 145 peers at 87.0% AFUE (the cohort floor across 663 certified series) for Max AFUE (-8.00% AFUE vs 95.0% AFUE category median) across 1 certified SKU combination. Non-condensing Oil model at 87.0% AFUE suited to Type B metal chimney venting with ENERGY STAR qualification dated 2021-11-08. Zero CPSC residential HVAC recall filings match PurePro in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #518 of 663 (146 tied at floor) | -8.00% AFUE vs 95.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Residential Boiler Minimum | PASS | Rated 87.0% AFUE vs 84% federal gas hot-water boiler baseline |
| Condensing Hydronic Design | CAST / NON-CONDENSING | Operates above flue dewpoint without condensate neutralization |
How much annual energy and operating cost does PurePro P3ES require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, PurePro P3ES estimates reflect 1 certified SKU combination tested under PD ID 2344438.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 574.7 therms/yr | 6,724 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $833/yr | State range: $425 (ID) to $2,902 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 50.3 therms/yr | $73/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to PurePro P3ES?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for PurePro P3ES (PD ID 2344438).
| P3ES | Matched AHRI Coil | — | / 87.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on PurePro P3ES, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across PurePro P3ES: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for PurePro P3ES exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- PurePro P3ES exhausts flue heat via Type B vent piping, lowering sealed efficiency vs condensing models.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal PurePro P3ES fit | Single-family replacement needing documented ENERGY STAR PD ID 2344438 with matching indoor air handler. |
| Skip PurePro P3ES if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential boiler models deliver similar efficiency?
Compare PurePro P3ES against Dunkirk Boilers EXB5100 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does PurePro P3ES compare with peer Residential Boiler units?
PurePro P3ES holds #518 of 663 (146 tied at floor) out of 663 verified residential boiler models (-8.00% AFUE vs 95.0% AFUE category median), spanning 1 certified SKU up to 87.0% AFUE. Closest same-cohort alternatives include Dunkirk Boilers EXB5100.
Where is PurePro P3ES compliant for 2026 US installation?
PurePro P3ES: ENERGY STAR certified residential boiler (87.0% AFUE). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does PurePro P3ES model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, PurePro P3ES runs 574.7 therms/yr across standard cooling/heating hours.
What capacity band and airflow does PurePro P3ES cover?
PurePro P3ES covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does PurePro P3ES handle extreme weather or cold snaps?
PurePro P3ES delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern PurePro P3ES?
PurePro P3ES specifies sealed combustion compliance (PD ID 2344438); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in PurePro P3ES reach 87.0% AFUE?
Peak 87.0% AFUE represents the top tested AHRI pairing for PurePro P3ES (PD ID 2344438); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to PurePro P3ES?
PurePro P3ES requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Dunkirk Boilers EXB5100.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages